Transcatheter Closure of a Chronic Iatrogenic Arteriovenous Fistula Between the Carotid Artery and the Brachiocephalic Vein with an Amplatzer Duct Occluder in Combination with a Carotid Stent
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F09%3A00201866" target="_blank" >RIV/00179906:_____/09:00201866 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/09:00209068
Výsledek na webu
<a href="http://link.springer.com/content/pdf/10.1007%2Fs00270-008-9438-x.pdf" target="_blank" >http://link.springer.com/content/pdf/10.1007%2Fs00270-008-9438-x.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00270-008-9438-x" target="_blank" >10.1007/s00270-008-9438-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Transcatheter Closure of a Chronic Iatrogenic Arteriovenous Fistula Between the Carotid Artery and the Brachiocephalic Vein with an Amplatzer Duct Occluder in Combination with a Carotid Stent
Popis výsledku v původním jazyce
We report an original method of transcatheter closure of an arteriovenous fistula using the combination of an Amplatzer PDA occluder and a carotid stent. The fistula was between the left carotid artery and the brachiocephalic vein. The patient had significant left-to-right shunt and was highly symptomatic. Due to the large orifice and pseudoaneurysmatic enlargement of the fistula, we had to use a large Amplatzer PDA occluder and the protruding part of the PDA device disk had to be covered with a carotidstent. The fistula was completely closed. The patient stopped having symptoms and, 2 years after the procedure, the effect persists.
Název v anglickém jazyce
Transcatheter Closure of a Chronic Iatrogenic Arteriovenous Fistula Between the Carotid Artery and the Brachiocephalic Vein with an Amplatzer Duct Occluder in Combination with a Carotid Stent
Popis výsledku anglicky
We report an original method of transcatheter closure of an arteriovenous fistula using the combination of an Amplatzer PDA occluder and a carotid stent. The fistula was between the left carotid artery and the brachiocephalic vein. The patient had significant left-to-right shunt and was highly symptomatic. Due to the large orifice and pseudoaneurysmatic enlargement of the fistula, we had to use a large Amplatzer PDA occluder and the protruding part of the PDA device disk had to be covered with a carotidstent. The fistula was completely closed. The patient stopped having symptoms and, 2 years after the procedure, the effect persists.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NS9742" target="_blank" >NS9742: Dokončení vývoje a výroba univerzální aparatůry pro měření minutového srdečních výdeje, zkratů a regurgitací</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cardiovascular and Interventional Radiology
ISSN
0174-1551
e-ISSN
—
Svazek periodika
32
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
568-571