Use of bio-degradable stents for the treatment of refractory benign gastrointestinal stenoses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F11%3A10104343" target="_blank" >RIV/00179906:_____/11:10104343 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/11:10104343
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of bio-degradable stents for the treatment of refractory benign gastrointestinal stenoses
Popis výsledku v původním jazyce
Bio-degradable stents are be made of different synthetic polymers (like polylactide or polyglycolide) or their co-polymers (polydioxanone). They can be used for treating benign stenoses of the small and large intestine, particularly in Crohn''s disease.Endoscopic introduction of bio-degradable stents into small and large intestinal stenoses is feasible and relatively simple. Initial results are encouraging and the complication rate is low. However, there are still some difficulties that need to be overcome. The rate or early stent migration is still rather high (up to one third of patients). This might be solved by changes in the shape or rigidity of the stents as well as by further improvement in the design. Proof of long-term efficacy and safety requires further studies.
Název v anglickém jazyce
Use of bio-degradable stents for the treatment of refractory benign gastrointestinal stenoses
Popis výsledku anglicky
Bio-degradable stents are be made of different synthetic polymers (like polylactide or polyglycolide) or their co-polymers (polydioxanone). They can be used for treating benign stenoses of the small and large intestine, particularly in Crohn''s disease.Endoscopic introduction of bio-degradable stents into small and large intestinal stenoses is feasible and relatively simple. Initial results are encouraging and the complication rate is low. However, there are still some difficulties that need to be overcome. The rate or early stent migration is still rather high (up to one third of patients). This might be solved by changes in the shape or rigidity of the stents as well as by further improvement in the design. Proof of long-term efficacy and safety requires further studies.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FE - Ostatní obory vnitřního lékařství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta medica (Hradec Králové) / Universitas Carolina, Facultas Medica Hradec Kralove
ISSN
1211-4286
e-ISSN
—
Svazek periodika
54
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
137-143
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—