Pitfalls and limitations of ZAP-70 detection in chronic lymphocytic leukemia
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F12%3A10124568" target="_blank" >RIV/00179906:_____/12:10124568 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/12:10124568
Výsledek na webu
<a href="http://dx.doi.org/10.1179/1607845412Y.0000000015" target="_blank" >http://dx.doi.org/10.1179/1607845412Y.0000000015</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1179/1607845412Y.0000000015" target="_blank" >10.1179/1607845412Y.0000000015</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pitfalls and limitations of ZAP-70 detection in chronic lymphocytic leukemia
Popis výsledku v původním jazyce
Zeta-associated protein of 70 kDa (ZAP-70) is a tyrosine kinase that plays a role in signal transduction from the T-cell receptor. ZAP-70 is expressed in normal T-cells and NK-cells. Increased expression of ZAP-70 has been identified in chronic lymphocytic leukemia (CLL). CLL patients with increased ZAP-70 expression have significantly worse prognosis in terms of both progression-free survival and overall survival. There are several methods to quantify ZAP-70: polymerase chain reaction (PCR), immunoblotting, immunohistochemistry, and flow cytometry. Use of flow cytometry for ZAP-70 detection seems to be advantageous as this technique enables us to assess the presence of ZAP-70 separately on CLL clone, T-cells, and NK-cells. On the other hand, detectionof ZAP-70 by flow cytometry is substantially influenced by many variables. The principal drawback of flow cytometry is the absence of consensus regarding selection of optimal anti-ZAP-70 antibody, fluorochrome conjugate, the most reliabl
Název v anglickém jazyce
Pitfalls and limitations of ZAP-70 detection in chronic lymphocytic leukemia
Popis výsledku anglicky
Zeta-associated protein of 70 kDa (ZAP-70) is a tyrosine kinase that plays a role in signal transduction from the T-cell receptor. ZAP-70 is expressed in normal T-cells and NK-cells. Increased expression of ZAP-70 has been identified in chronic lymphocytic leukemia (CLL). CLL patients with increased ZAP-70 expression have significantly worse prognosis in terms of both progression-free survival and overall survival. There are several methods to quantify ZAP-70: polymerase chain reaction (PCR), immunoblotting, immunohistochemistry, and flow cytometry. Use of flow cytometry for ZAP-70 detection seems to be advantageous as this technique enables us to assess the presence of ZAP-70 separately on CLL clone, T-cells, and NK-cells. On the other hand, detectionof ZAP-70 by flow cytometry is substantially influenced by many variables. The principal drawback of flow cytometry is the absence of consensus regarding selection of optimal anti-ZAP-70 antibody, fluorochrome conjugate, the most reliabl
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FN - Epidemiologie, infekční nemoci a klinická imunologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT13412" target="_blank" >NT13412: Komplexní hodnocení vlivu mikroprostředí na klinický průběh chronické lymfocytární leukémie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Hematology
ISSN
1024-5332
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
268-274
Kód UT WoS článku
000308350000004
EID výsledku v databázi Scopus
—