Clinical evaluation of the intestinal microcirculation using sidestream dark field imaging - Recommendations of a round table meeting
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F14%3A10281561" target="_blank" >RIV/00179906:_____/14:10281561 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/14:10281561
Výsledek na webu
<a href="http://dx.doi.org/10.3233/CH-141810" target="_blank" >http://dx.doi.org/10.3233/CH-141810</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3233/CH-141810" target="_blank" >10.3233/CH-141810</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Clinical evaluation of the intestinal microcirculation using sidestream dark field imaging - Recommendations of a round table meeting
Popis výsledku v původním jazyce
In clinical setting, Sidestream Dark Field (SDF) imaging has provided unprecedented insights into the gut microcirculation mainly by studying the intestinal mucosa of patients with ileostomies. Visualizing microvascular structure and function of ileal mucosa at the bedside brings unique opportunity for clinical research, particularly in critically ill patients. Several papers that were focused on intestinal microcirculation, used different methods of assessment because an accepted scoring systems does not exist so far and it is no surprise that it is rather difficult to compare the results from these studies. The present paper presents recommendations concerning specific aspects of image acquisition and proposes some parameters for the description of the intestinal microcirculation in human studies, as suggested by the participants of a round table meeting. The round table meeting participants reviewed all relevant literature, discussed various aspects of image acquisition by SDF techn
Název v anglickém jazyce
Clinical evaluation of the intestinal microcirculation using sidestream dark field imaging - Recommendations of a round table meeting
Popis výsledku anglicky
In clinical setting, Sidestream Dark Field (SDF) imaging has provided unprecedented insights into the gut microcirculation mainly by studying the intestinal mucosa of patients with ileostomies. Visualizing microvascular structure and function of ileal mucosa at the bedside brings unique opportunity for clinical research, particularly in critically ill patients. Several papers that were focused on intestinal microcirculation, used different methods of assessment because an accepted scoring systems does not exist so far and it is no surprise that it is rather difficult to compare the results from these studies. The present paper presents recommendations concerning specific aspects of image acquisition and proposes some parameters for the description of the intestinal microcirculation in human studies, as suggested by the participants of a round table meeting. The round table meeting participants reviewed all relevant literature, discussed various aspects of image acquisition by SDF techn
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FE - Ostatní obory vnitřního lékařství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Clinical Hemorheology and Microcirculation
ISSN
1386-0291
e-ISSN
—
Svazek periodika
57
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
10
Strana od-do
137-146
Kód UT WoS článku
000341927400007
EID výsledku v databázi Scopus
—