Biochip array technology and evaluation of serum levels of multiple cytokines and adhesion molecules in patients with newly diagnosed acute myeloid leukemia
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F14%3A10288636" target="_blank" >RIV/00179906:_____/14:10288636 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60162694:G44__/14:43875085 RIV/00216208:11150/14:10288636
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biochip array technology and evaluation of serum levels of multiple cytokines and adhesion molecules in patients with newly diagnosed acute myeloid leukemia
Popis výsledku v původním jazyce
Evaluation of serum levels of 17 cytokines and 5 adhesion molecules in patients with newly diagnosed acute myeloid leukemia (AML) and in healthy subjects using biochip array technology. Methods: A total of 15 AML patients and 15 healthy subjects (blood donors) were studied. Serum samples were analyzed by biochip based immunoassays on the Evidence Investigator analyzer. This approach allows multi-analytical determination from a single sample. T-tests were used for statistical analysis. Results: In newlydiagnosed AML patients, we found significant increase (p < 0.01) in serum VCAM-1, ICAM-1, E-selectin, L-selectin, and significant increase (p < 0.05) in serum IL-6, IL-8. No significant differences were found in the levels of other evaluated cytokines and adhesion molecules. Conclusion: Our results indicate that serum levels of specific cytokines and adhesion molecules ( VCAM-1, ICAM-1, E-selectin, L-selectin, IL-6, IL-8) are significantly altered in patients with newly diagnosed AML, sh
Název v anglickém jazyce
Biochip array technology and evaluation of serum levels of multiple cytokines and adhesion molecules in patients with newly diagnosed acute myeloid leukemia
Popis výsledku anglicky
Evaluation of serum levels of 17 cytokines and 5 adhesion molecules in patients with newly diagnosed acute myeloid leukemia (AML) and in healthy subjects using biochip array technology. Methods: A total of 15 AML patients and 15 healthy subjects (blood donors) were studied. Serum samples were analyzed by biochip based immunoassays on the Evidence Investigator analyzer. This approach allows multi-analytical determination from a single sample. T-tests were used for statistical analysis. Results: In newlydiagnosed AML patients, we found significant increase (p < 0.01) in serum VCAM-1, ICAM-1, E-selectin, L-selectin, and significant increase (p < 0.05) in serum IL-6, IL-8. No significant differences were found in the levels of other evaluated cytokines and adhesion molecules. Conclusion: Our results indicate that serum levels of specific cytokines and adhesion molecules ( VCAM-1, ICAM-1, E-selectin, L-selectin, IL-6, IL-8) are significantly altered in patients with newly diagnosed AML, sh
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Experimental Oncology
ISSN
1812-9269
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
UA - Ukrajina
Počet stran výsledku
2
Strana od-do
50-51
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—