Precise Temperature Measurement for Increasing the Survival of Newborn Babies in Incubator Environments
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F14%3A10288952" target="_blank" >RIV/00179906:_____/14:10288952 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62690094:18450/14:50003034 RIV/61989100:27360/14:86092122
Výsledek na webu
<a href="http://www.mdpi.com/1424-8220/14/12/23563/htm" target="_blank" >http://www.mdpi.com/1424-8220/14/12/23563/htm</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s141223563" target="_blank" >10.3390/s141223563</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Precise Temperature Measurement for Increasing the Survival of Newborn Babies in Incubator Environments
Popis výsledku v původním jazyce
Precise temperature measurement is essential in a wide range of applications in the medical environment, however the regarding the problem of temperature measurement inside a simple incubator, neither a simple nor a low cost solution have been proposed yet. Given that standard temperature sensors don't satisfy the necessary expectations, the problem is not measuring temperature, but rather achieving the desired sensitivity. In response, this paper introduces a novel hardware design as well as the implementation that increases measurement sensitivity in defined temperature intervals at low cost.
Název v anglickém jazyce
Precise Temperature Measurement for Increasing the Survival of Newborn Babies in Incubator Environments
Popis výsledku anglicky
Precise temperature measurement is essential in a wide range of applications in the medical environment, however the regarding the problem of temperature measurement inside a simple incubator, neither a simple nor a low cost solution have been proposed yet. Given that standard temperature sensors don't satisfy the necessary expectations, the problem is not measuring temperature, but rather achieving the desired sensitivity. In response, this paper introduces a novel hardware design as well as the implementation that increases measurement sensitivity in defined temperature intervals at low cost.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors
ISSN
1424-8220
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
18
Strana od-do
23563-23580
Kód UT WoS článku
000346794300071
EID výsledku v databázi Scopus
—