Electrophysiology and colour: a comparison of methods to evaluate inner retinal function
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F15%3A10313891" target="_blank" >RIV/00179906:_____/15:10313891 - isvavai.cz</a>
Výsledek na webu
<a href="http://link.springer.com/article/10.1007%2Fs10633-015-9512-z" target="_blank" >http://link.springer.com/article/10.1007%2Fs10633-015-9512-z</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10633-015-9512-z" target="_blank" >10.1007/s10633-015-9512-z</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrophysiology and colour: a comparison of methods to evaluate inner retinal function
Popis výsledku v původním jazyce
Several methods are used for the clinical examination of inner retinal function. The aims of this study were to compare four methods that can be used for the diagnosis and monitoring of the diseases diabetes and glaucoma. We examine correlations between results and determine which method is most sensitive for detecting disease. Twenty control subjects, 12 patients with early glaucoma and 8 patients with diabetes mellitus were enrolled in the study. All underwent 4 examinations: transient full-field pattern electroretinogram (PERG), multifocal pattern electroretinogram (mfPERG), chromatic contrast threshold measurements (protan and tritan) and blue-on yellow (SWAP) perimetry. For the total cohort of 40 subjects, the results show a significant correlation between the amplitudes of the PERG and those of the mfPERG, as well between the tritan contrast thresholds and the SWAP MD. Furthermore, ROC analyses reveal that colour contrast thresholds could significantly distinguish between the patient and the control group. Glaucoma patients alone could also be distinguished. We conclude that there is no large correlation between the results of methods, if differing pathways
Název v anglickém jazyce
Electrophysiology and colour: a comparison of methods to evaluate inner retinal function
Popis výsledku anglicky
Several methods are used for the clinical examination of inner retinal function. The aims of this study were to compare four methods that can be used for the diagnosis and monitoring of the diseases diabetes and glaucoma. We examine correlations between results and determine which method is most sensitive for detecting disease. Twenty control subjects, 12 patients with early glaucoma and 8 patients with diabetes mellitus were enrolled in the study. All underwent 4 examinations: transient full-field pattern electroretinogram (PERG), multifocal pattern electroretinogram (mfPERG), chromatic contrast threshold measurements (protan and tritan) and blue-on yellow (SWAP) perimetry. For the total cohort of 40 subjects, the results show a significant correlation between the amplitudes of the PERG and those of the mfPERG, as well between the tritan contrast thresholds and the SWAP MD. Furthermore, ROC analyses reveal that colour contrast thresholds could significantly distinguish between the patient and the control group. Glaucoma patients alone could also be distinguished. We conclude that there is no large correlation between the results of methods, if differing pathways
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FF - ORL, oftalmologie, stomatologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Documenta Ophthalmologica
ISSN
0012-4486
e-ISSN
—
Svazek periodika
131
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
159-167
Kód UT WoS článku
000365757200001
EID výsledku v databázi Scopus
2-s2.0-84948564022