Development and validation of a FIA/UV-vis method for pK(a) determination of oxime based acetylcholinesterase reactivators
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F16%3A10321990" target="_blank" >RIV/00179906:_____/16:10321990 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62690094:18470/16:50003972
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0731708515301515" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0731708515301515</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jpba.2015.09.010" target="_blank" >10.1016/j.jpba.2015.09.010</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development and validation of a FIA/UV-vis method for pK(a) determination of oxime based acetylcholinesterase reactivators
Popis výsledku v původním jazyce
Acetylcholinesterase reactivators (oximes) are compounds used for antidotal treatment in case of organophosphorus poisoning. The dissociation constants (pK(a1)) of ten standard or promising acetylcholinesterase reactivators were determined by ultraviolet absorption spectrometry. Two methods of spectra measurement (UV-vis spectrometry, FIA/UV-vis) were applied and compared. The soft and hard models for calculation of pK(a1) values were performed. The pK(a1) values were recommended in the range 7.00-8.35, where at least 10% of oximate anion is available for organophosphate reactivation. All tested oximes were found to have pK(a1) in this range. The FIA/UV-vis method provided rapid sample throughput, low sample consumption, high sensitivity and precision compared to standard UV-vis method. The hard calculation model was proposed as more accurate for pK(a1) calculation.
Název v anglickém jazyce
Development and validation of a FIA/UV-vis method for pK(a) determination of oxime based acetylcholinesterase reactivators
Popis výsledku anglicky
Acetylcholinesterase reactivators (oximes) are compounds used for antidotal treatment in case of organophosphorus poisoning. The dissociation constants (pK(a1)) of ten standard or promising acetylcholinesterase reactivators were determined by ultraviolet absorption spectrometry. Two methods of spectra measurement (UV-vis spectrometry, FIA/UV-vis) were applied and compared. The soft and hard models for calculation of pK(a1) values were performed. The pK(a1) values were recommended in the range 7.00-8.35, where at least 10% of oximate anion is available for organophosphate reactivation. All tested oximes were found to have pK(a1) in this range. The FIA/UV-vis method provided rapid sample throughput, low sample consumption, high sensitivity and precision compared to standard UV-vis method. The hard calculation model was proposed as more accurate for pK(a1) calculation.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FR - Farmakologie a lékárnická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Pharmaceutical and Biomedical Analysis
ISSN
0731-7085
e-ISSN
—
Svazek periodika
117
Číslo periodika v rámci svazku
January
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
240-246
Kód UT WoS článku
000365145500030
EID výsledku v databázi Scopus
2-s2.0-84941890716