Adverse events in apheresis: An update of the WAA registry data
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F16%3A10331717" target="_blank" >RIV/00179906:_____/16:10331717 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/16:10331717 RIV/00843989:_____/16:E0105401
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.transci.2016.01.003" target="_blank" >http://dx.doi.org/10.1016/j.transci.2016.01.003</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.transci.2016.01.003" target="_blank" >10.1016/j.transci.2016.01.003</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Adverse events in apheresis: An update of the WAA registry data
Popis výsledku v původním jazyce
Apheresis with different procedures and devices are used for a variety of indications that may have different adverse events (AEs). The aim of this study was to clarify the extent and possible reasons of various side effects based on data from a multinational registry. The WAA-apheresis registry data focus on adverse events in a total of 50846 procedures in 7142 patients (42% women). AEs were graded as mild, moderate (need for medication), severe (interruption due to the AE) or death (due to AE). More AEs occurred during the first procedures versus subsequent (8.4 and 5.5%, respectively). AEs were mild in 2.4% (due to access 54%, device 7%, hypotension 15%, tingling 8%), moderate in 3% (tingling 58%, urticaria 15%, hypotension 10%, nausea 3%), and severe in 0.4% of procedures (syncope/hypotension 32%, urticaria 17%, chills/fever 8%, arrhythmia/asystole 4.5%, nausea/vomiting 4%). Hypotension was most common if albumin was used as the replacement fluid, and urticaria when plasma was used. Arrhythmia occurred to similar extents when using plasma or albumin as replacement. In 64% of procedures with bronchospasm, plasma was part of the replacement fluid used. Severe AEs are rare. Although most reactions are mild and moderate, several side effects may be critical for the patient. We present side effects in relation to the procedures and suggest that safety is increased by regular vital sign measurements, cardiac monitoring and by having emergency equipment nearby.
Název v anglickém jazyce
Adverse events in apheresis: An update of the WAA registry data
Popis výsledku anglicky
Apheresis with different procedures and devices are used for a variety of indications that may have different adverse events (AEs). The aim of this study was to clarify the extent and possible reasons of various side effects based on data from a multinational registry. The WAA-apheresis registry data focus on adverse events in a total of 50846 procedures in 7142 patients (42% women). AEs were graded as mild, moderate (need for medication), severe (interruption due to the AE) or death (due to AE). More AEs occurred during the first procedures versus subsequent (8.4 and 5.5%, respectively). AEs were mild in 2.4% (due to access 54%, device 7%, hypotension 15%, tingling 8%), moderate in 3% (tingling 58%, urticaria 15%, hypotension 10%, nausea 3%), and severe in 0.4% of procedures (syncope/hypotension 32%, urticaria 17%, chills/fever 8%, arrhythmia/asystole 4.5%, nausea/vomiting 4%). Hypotension was most common if albumin was used as the replacement fluid, and urticaria when plasma was used. Arrhythmia occurred to similar extents when using plasma or albumin as replacement. In 64% of procedures with bronchospasm, plasma was part of the replacement fluid used. Severe AEs are rare. Although most reactions are mild and moderate, several side effects may be critical for the patient. We present side effects in relation to the procedures and suggest that safety is increased by regular vital sign measurements, cardiac monitoring and by having emergency equipment nearby.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Transfusion and Apheresis Science
ISSN
1473-0502
e-ISSN
—
Svazek periodika
54
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
14
Strana od-do
2-15
Kód UT WoS článku
000374614700002
EID výsledku v databázi Scopus
2-s2.0-84954304755