Vena cava filters in patients presenting with major bleeding during anticoagulation for venous thromboembolism
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F19%3A10400440" target="_blank" >RIV/00179906:_____/19:10400440 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=31BZyXHseW" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=31BZyXHseW</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s11739-019-02077-5" target="_blank" >10.1007/s11739-019-02077-5</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Vena cava filters in patients presenting with major bleeding during anticoagulation for venous thromboembolism
Popis výsledku v původním jazyce
The association between inferior vena cava filter (IVC) use and outcome in patients presenting with major bleeding during anticoagulation for venous thromboembolism (VTE) has not been thoroughly investigated. We used the RIETE registry to compare the 30-day outcomes (death, major re-bleeding or VTE recurrences) in VTE patients who bled during the first 3 months of therapy, regarding the insertion of an IVC filter. A propensity score matched (PSM) analysis was performed to adjust for potential confounders. From January 2001 to September 2016, 1065 VTE patients had major bleeding during the first 3 months of anticoagulation (gastrointestinal 370; intracranial 124). Of these, 122 patients (11%) received an IVC filter. Patients receiving a filter restarted anticoagulation later (median, 4 vs. 2 days) and at lower doses (95 +/- 52 IU/kg/day vs. 104 +/- 55 of low-molecular-weight heparin) than those not receiving a filter. During the first 30 days after bleeding (after excluding 246 patients who died within the first 24 h), 283 patients (27%) died, 63 (5.9%) had non-fatal re-bleeding and 19 (1.8%) had recurrent pulmonary embolism (PE). In PSM analysis, patients receiving an IVC filter (n = 122) had a lower risk for all-cause death (HR 0.49; 95% CI 0.31-0.77) or fatal bleeding (HR 0.16; 95% CI 0.07-0.49) and a similar risk for re-bleeding (HR 0.55; 95% CI 0.23-1.40) or PE recurrences (HR 1.57; 95% CI 0.38-6.36) than those not receiving a filter (n = 429). In VTE patients experiencing major bleeding during the first 3 months, use of an IVC filter was associated with reduced mortality rates. Clinical Trial Registration NCT02832245.
Název v anglickém jazyce
Vena cava filters in patients presenting with major bleeding during anticoagulation for venous thromboembolism
Popis výsledku anglicky
The association between inferior vena cava filter (IVC) use and outcome in patients presenting with major bleeding during anticoagulation for venous thromboembolism (VTE) has not been thoroughly investigated. We used the RIETE registry to compare the 30-day outcomes (death, major re-bleeding or VTE recurrences) in VTE patients who bled during the first 3 months of therapy, regarding the insertion of an IVC filter. A propensity score matched (PSM) analysis was performed to adjust for potential confounders. From January 2001 to September 2016, 1065 VTE patients had major bleeding during the first 3 months of anticoagulation (gastrointestinal 370; intracranial 124). Of these, 122 patients (11%) received an IVC filter. Patients receiving a filter restarted anticoagulation later (median, 4 vs. 2 days) and at lower doses (95 +/- 52 IU/kg/day vs. 104 +/- 55 of low-molecular-weight heparin) than those not receiving a filter. During the first 30 days after bleeding (after excluding 246 patients who died within the first 24 h), 283 patients (27%) died, 63 (5.9%) had non-fatal re-bleeding and 19 (1.8%) had recurrent pulmonary embolism (PE). In PSM analysis, patients receiving an IVC filter (n = 122) had a lower risk for all-cause death (HR 0.49; 95% CI 0.31-0.77) or fatal bleeding (HR 0.16; 95% CI 0.07-0.49) and a similar risk for re-bleeding (HR 0.55; 95% CI 0.23-1.40) or PE recurrences (HR 1.57; 95% CI 0.38-6.36) than those not receiving a filter (n = 429). In VTE patients experiencing major bleeding during the first 3 months, use of an IVC filter was associated with reduced mortality rates. Clinical Trial Registration NCT02832245.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Internal and Emergency Medicine
ISSN
1828-0447
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
12
Strana od-do
1101-1112
Kód UT WoS článku
000491585400013
EID výsledku v databázi Scopus
2-s2.0-85065297770