Sense and Nonsense of Elevated Column Temperature in Proteomic Bottom-up LC-MS Analyses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F21%3A10428644" target="_blank" >RIV/00179906:_____/21:10428644 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11160/21:10428644
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=5tj.0cK2ij" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=5tj.0cK2ij</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acs.jproteome.0c00479" target="_blank" >10.1021/acs.jproteome.0c00479</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sense and Nonsense of Elevated Column Temperature in Proteomic Bottom-up LC-MS Analyses
Popis výsledku v původním jazyce
Elevated column temperature represents a simple means for improving chromatographic separation of peptides. Here, we demonstrated the advantages of the column temperature in peptide separation using state-of-the-art columns. More importantly, we also determined how temperature can impair proteomic bottom-up analyses. We found that an elevated temperature in combination with the acidic pH of the mobile phase induced in-column peptide hydrolysis with high specificity to Asp and accelerated five modification reactions of amino acids. The positive effects of temperature dominated in the 30 min long gradients since the column operated at 90 degrees C provided the largest number of identified peptides and proteins. However, the adverse effects of temperature on peptide integrity in longer liquid chromatography-mass spectrometry (LC-MS) analyses required its reduction to obtain optimum results. The largest number of peptides was identified using the column maintained at 75 degrees C in 60 min long gradients, at 60 degrees C in 120 min long gradients, and at 45 degrees C in 240 min long gradients. Our results indicate that no universal column temperature exists for bottom-up LC-MS analyses. Quite the contrary, the temperature setting must be selected rationally to exploit the full capabilities of the state-of-the-art mass spectrometers in proteomic LC-MS analyses, with the gradient time being a critical factor.
Název v anglickém jazyce
Sense and Nonsense of Elevated Column Temperature in Proteomic Bottom-up LC-MS Analyses
Popis výsledku anglicky
Elevated column temperature represents a simple means for improving chromatographic separation of peptides. Here, we demonstrated the advantages of the column temperature in peptide separation using state-of-the-art columns. More importantly, we also determined how temperature can impair proteomic bottom-up analyses. We found that an elevated temperature in combination with the acidic pH of the mobile phase induced in-column peptide hydrolysis with high specificity to Asp and accelerated five modification reactions of amino acids. The positive effects of temperature dominated in the 30 min long gradients since the column operated at 90 degrees C provided the largest number of identified peptides and proteins. However, the adverse effects of temperature on peptide integrity in longer liquid chromatography-mass spectrometry (LC-MS) analyses required its reduction to obtain optimum results. The largest number of peptides was identified using the column maintained at 75 degrees C in 60 min long gradients, at 60 degrees C in 120 min long gradients, and at 45 degrees C in 240 min long gradients. Our results indicate that no universal column temperature exists for bottom-up LC-MS analyses. Quite the contrary, the temperature setting must be selected rationally to exploit the full capabilities of the state-of-the-art mass spectrometers in proteomic LC-MS analyses, with the gradient time being a critical factor.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
<a href="/cs/project/EF15_003%2F0000465" target="_blank" >EF15_003/0000465: Vytvoření expertního týmu pro pokročilý výzkum v separačních vědách</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Proteome Research
ISSN
1535-3893
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
13
Strana od-do
420-432
Kód UT WoS článku
000605145400037
EID výsledku v databázi Scopus
2-s2.0-85096050695