Blood loss quantification during major abdominal surgery: prospective observational cohort study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F24%3A10478544" target="_blank" >RIV/00179906:_____/24:10478544 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60162694:G44__/25:00561893
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=bbcrpRHW1_" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=bbcrpRHW1_</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s12893-023-02288-w" target="_blank" >10.1186/s12893-023-02288-w</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Blood loss quantification during major abdominal surgery: prospective observational cohort study
Popis výsledku v původním jazyce
BackgroundBlood loss during major abdominal surgery is an essential parameter in the evaluation of strategies aimed at reducing perioperative bleeding. However, blood loss quantification remains unreliable and inaccurate. The aim of this study was to compare several methods of blood loss quantification-visual estimation by surgeon and anesthesiologist, the gravimetric method, the calculation method with spectrophotometric measurement. The spectrophotometric measurement is considered as the most accurate method.MethodsThe study was designed as a prospective observational cohort single-center study. We analyzed 61 patients who underwent elective liver or pancreatic resection. The anesthesiologists' and surgeons' estimate of blood loss was based on a visual assessment. The gravimetric method was based on weighing the suction canister and surgical drapes before and after use. The basis of calculation method was anthropometric and hematological parameters, we used Lopez-Picado's formula. The spectrophotometric method was based on the spectrophotometric determination of hemoglobin mass in the lost blood. We compared the methods using paired t-test, non-parametric Wilcoxon test and Bland-Altman analysis.ResultsVisual estimation by surgeons and anesthesiologists, gravimetric measurement, and calculation method were significantly different from spectrophotometric measurement at the significance level alpha = 0.05. All methods overestimated blood loss which was measured by spectrophotometric method. The estimate by surgeons was the closest to the spectrophotometric measurement, difference 68.7 ml (95% confidence interval [CI]: -129.3--8.2).ConclusionsWe conclude that the estimate of blood loss by surgeons and anesthesiologists, as well as gravimetric method and calculation method are all significantly inaccurate in real surgical setting. We did not confirm the commonly accepted assumption that surgeons underestimate the blood loss.Trial registrationThe study was registered under the title " Blood Loss Quantification During Major Abdominal Surgery" at ClinicalTrials.gov with the registration number NCT05316649. Date of the first registration was 20/3/2022.
Název v anglickém jazyce
Blood loss quantification during major abdominal surgery: prospective observational cohort study
Popis výsledku anglicky
BackgroundBlood loss during major abdominal surgery is an essential parameter in the evaluation of strategies aimed at reducing perioperative bleeding. However, blood loss quantification remains unreliable and inaccurate. The aim of this study was to compare several methods of blood loss quantification-visual estimation by surgeon and anesthesiologist, the gravimetric method, the calculation method with spectrophotometric measurement. The spectrophotometric measurement is considered as the most accurate method.MethodsThe study was designed as a prospective observational cohort single-center study. We analyzed 61 patients who underwent elective liver or pancreatic resection. The anesthesiologists' and surgeons' estimate of blood loss was based on a visual assessment. The gravimetric method was based on weighing the suction canister and surgical drapes before and after use. The basis of calculation method was anthropometric and hematological parameters, we used Lopez-Picado's formula. The spectrophotometric method was based on the spectrophotometric determination of hemoglobin mass in the lost blood. We compared the methods using paired t-test, non-parametric Wilcoxon test and Bland-Altman analysis.ResultsVisual estimation by surgeons and anesthesiologists, gravimetric measurement, and calculation method were significantly different from spectrophotometric measurement at the significance level alpha = 0.05. All methods overestimated blood loss which was measured by spectrophotometric method. The estimate by surgeons was the closest to the spectrophotometric measurement, difference 68.7 ml (95% confidence interval [CI]: -129.3--8.2).ConclusionsWe conclude that the estimate of blood loss by surgeons and anesthesiologists, as well as gravimetric method and calculation method are all significantly inaccurate in real surgical setting. We did not confirm the commonly accepted assumption that surgeons underestimate the blood loss.Trial registrationThe study was registered under the title " Blood Loss Quantification During Major Abdominal Surgery" at ClinicalTrials.gov with the registration number NCT05316649. Date of the first registration was 20/3/2022.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30212 - Surgery
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
BMC Surgery
ISSN
1471-2482
e-ISSN
1471-2482
Svazek periodika
24
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
5
Kód UT WoS článku
001138079000002
EID výsledku v databázi Scopus
2-s2.0-85181248259