Longitudinal outcomes following international multicentre experience with robotic aortic valve replacement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F25%3A10496721" target="_blank" >RIV/00179906:_____/25:10496721 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/25:10496721 RIV/00064203:_____/25:10496721
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=WlCKl_CSrX" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=WlCKl_CSrX</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/ejcts/ezaf103" target="_blank" >10.1093/ejcts/ezaf103</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Longitudinal outcomes following international multicentre experience with robotic aortic valve replacement
Popis výsledku v původním jazyce
OBJECTIVES: In an effort to maintain the technical aspects of traditional prosthetic surgical aortic valve replacement (AVR) while reducing invasiveness and facilitate options for concomitant operations, transaxillary lateral mini-thoracotomy endoscopic robotic-assisted aortic valve replacment (RAVR) has been introduced. The present data highlights the contemporary international collaborative experience. METHODS: All consecutive patients undergoing standardized RAVR across 10 international sites (1/2020-7/2024) were evaluated using a central database with 1 year follow-up. RESULTS: A total of 300 patients were analyzed with a median predicted risk of 1.6% with aortic stenosis in 85.7%, nearly half with bicuspid valves. Biological prostheses were implanted in 220 (73.3%) with a median valve size 23 mm, 10% receiving aortic root enlargement, with 17% of all patients undergoing concomitant procedures. Median cross-clamp 120 min with no conversions to sternotomy. Median length of stay was 5 days, 4.3% with prolonged ventilation, 1.7% renal failure, 1.0% stroke, 8.3% required re-thoracotomy for evacuation of haemothorax. There were two 30-day operative mortalities (0.7%). The new permanent pacemaker rate for the full cohort was 2.6%. Of 163 patients with complete 1-year clinical and echocardiographic follow-up, mean aortic valve gradient was 10 mmHg and all but two patients (1.2%) had trace to no prosthetic or paravalvular insufficiency. CONCLUSIONS: RAVR is safe and effective, providing the reproducible benefits of surgical AVR while affording a less invasive approach that permits the opportunity for concomitant procedures. For low and intermediate risk patients with aortic valve disease, RAVR is a potential reproducible alternative for patients and heart teams.
Název v anglickém jazyce
Longitudinal outcomes following international multicentre experience with robotic aortic valve replacement
Popis výsledku anglicky
OBJECTIVES: In an effort to maintain the technical aspects of traditional prosthetic surgical aortic valve replacement (AVR) while reducing invasiveness and facilitate options for concomitant operations, transaxillary lateral mini-thoracotomy endoscopic robotic-assisted aortic valve replacment (RAVR) has been introduced. The present data highlights the contemporary international collaborative experience. METHODS: All consecutive patients undergoing standardized RAVR across 10 international sites (1/2020-7/2024) were evaluated using a central database with 1 year follow-up. RESULTS: A total of 300 patients were analyzed with a median predicted risk of 1.6% with aortic stenosis in 85.7%, nearly half with bicuspid valves. Biological prostheses were implanted in 220 (73.3%) with a median valve size 23 mm, 10% receiving aortic root enlargement, with 17% of all patients undergoing concomitant procedures. Median cross-clamp 120 min with no conversions to sternotomy. Median length of stay was 5 days, 4.3% with prolonged ventilation, 1.7% renal failure, 1.0% stroke, 8.3% required re-thoracotomy for evacuation of haemothorax. There were two 30-day operative mortalities (0.7%). The new permanent pacemaker rate for the full cohort was 2.6%. Of 163 patients with complete 1-year clinical and echocardiographic follow-up, mean aortic valve gradient was 10 mmHg and all but two patients (1.2%) had trace to no prosthetic or paravalvular insufficiency. CONCLUSIONS: RAVR is safe and effective, providing the reproducible benefits of surgical AVR while affording a less invasive approach that permits the opportunity for concomitant procedures. For low and intermediate risk patients with aortic valve disease, RAVR is a potential reproducible alternative for patients and heart teams.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Journal of Cardio-Thoracic Surgery
ISSN
1010-7940
e-ISSN
1873-734X
Svazek periodika
67
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
ezaf103
Kód UT WoS článku
001472681200001
EID výsledku v databázi Scopus
2-s2.0-105003746045