Electrochemical sensing of interaction of anterior gradient-2 protein with peptides at a charged interface
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00209805%3A_____%2F18%3A00077979" target="_blank" >RIV/00209805:_____/18:00077979 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081707:_____/18:00492336
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0013468618304663" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0013468618304663</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.electacta.2018.02.152" target="_blank" >10.1016/j.electacta.2018.02.152</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical sensing of interaction of anterior gradient-2 protein with peptides at a charged interface
Popis výsledku v původním jazyce
Anterior gradient-2 protein (AGR2) is overexpressed in many human cancers, and this protein presents a novel promising cancer biomarker. We show significant progress in understanding of the electric field effects on AGR2-peptides complexes using constant current chronopotentiometric stripping (CPS) analysis. Surface-attached AGR2-peptide complexes can be disintegrated as a result of their exposure to negative potentials. By controlling the exposure time and temperature, peaks of weakly bound nonspecific complexes can be discriminated from tightly bound specific complexes. Using CPS analysis we found that mutant E60A-AGR2 forms weaker complex with peptide aptamer in comparison to wild type AGR2. These data highlight the utility of this method for studying real-time dynamics of surface-attached protein-peptide complexes.
Název v anglickém jazyce
Electrochemical sensing of interaction of anterior gradient-2 protein with peptides at a charged interface
Popis výsledku anglicky
Anterior gradient-2 protein (AGR2) is overexpressed in many human cancers, and this protein presents a novel promising cancer biomarker. We show significant progress in understanding of the electric field effects on AGR2-peptides complexes using constant current chronopotentiometric stripping (CPS) analysis. Surface-attached AGR2-peptide complexes can be disintegrated as a result of their exposure to negative potentials. By controlling the exposure time and temperature, peaks of weakly bound nonspecific complexes can be discriminated from tightly bound specific complexes. Using CPS analysis we found that mutant E60A-AGR2 forms weaker complex with peptide aptamer in comparison to wild type AGR2. These data highlight the utility of this method for studying real-time dynamics of surface-attached protein-peptide complexes.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrochimica Acta
ISSN
0013-4686
e-ISSN
—
Svazek periodika
269
Číslo periodika v rámci svazku
10.4.2018
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
75
Strana od-do
70
Kód UT WoS článku
000428806700009
EID výsledku v databázi Scopus
2-s2.0-85042718704