Popis výsledku v původním jazyce
Background: The EuroMISE Minimal Data Model for Cardiology (MDMC) has been prepared by clinicians for clinical study in 2002. This model has been successfully implemented in an application for clinical data gathering. HL7 v3 Domain Analysis Model: Cardiology, Release 2 (HL7 DAM) has been published in HL7 September 2011 Ballot. Objectives: The objective of this paper is to compare these two data models. The main motivations for the comparison are nearly identical ways of development, and the same formatof both specifications. Methods: HL7 DAM is much broader than EuroMISE MDMC. Thus I focus only on data elements present in MDMC but absent in HL7 DAM. Also different scales of elements present in both models are compared. Results: I have found 25 elements out of 181 elements defined in MDMC which are not contained in HL7 DAM.
Název v anglickém jazyce
Comparison of EuroMISE Minimal Data Model for Cardiology and HL7 V3 DAM: Cardiology Rel. 2
Popis výsledku anglicky
Background: The EuroMISE Minimal Data Model for Cardiology (MDMC) has been prepared by clinicians for clinical study in 2002. This model has been successfully implemented in an application for clinical data gathering. HL7 v3 Domain Analysis Model: Cardiology, Release 2 (HL7 DAM) has been published in HL7 September 2011 Ballot. Objectives: The objective of this paper is to compare these two data models. The main motivations for the comparison are nearly identical ways of development, and the same formatof both specifications. Methods: HL7 DAM is much broader than EuroMISE MDMC. Thus I focus only on data elements present in MDMC but absent in HL7 DAM. Also different scales of elements present in both models are compared. Results: I have found 25 elements out of 181 elements defined in MDMC which are not contained in HL7 DAM.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
IN - Informatika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M06014" target="_blank" >1M06014: Centrum biomedicínské informatiky (CBI)</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Journal for Biomedical Informatics
ISSN
1801-5603
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
33-36
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—