Pig Model of Pulmonary Embolism: Where Is the Hemodynamic Break Point?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F13%3A10189743" target="_blank" >RIV/00216208:11110/13:10189743 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064165:_____/13:10189743
Výsledek na webu
<a href="http://www.biomed.cas.cz/physiolres/pdf/62%20Suppl%201/62_S173.pdf" target="_blank" >http://www.biomed.cas.cz/physiolres/pdf/62%20Suppl%201/62_S173.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pig Model of Pulmonary Embolism: Where Is the Hemodynamic Break Point?
Popis výsledku v původním jazyce
Early recognition of collapsing hemodynamics in pulmonary embolism is necessary to avoid cardiac arrest using aggressive medical therapy or mechanical cardiac support. The aim of the study was to identify the maximal acute hemodynamic compensatory steadystate. Overall, 40 dynamic obstructions of pulmonary artery were performed and hemodynamic data were collected. Occlusion of only left or right pulmonary artery did not lead to the hemodynamic collapse. When gradually obstructing the bifurcation, the right ventricle end-diastolic area expanded proportionally to pulmonary artery mean pressure from 11.6 (10.1, 14.1) to 17.8 (16.1, 18.8) cm(2) (p<0.0001) and pulmonary artery mean pressure increased from 22 (20, 24) to 44 (41, 47) mmHg (p<0.0001) at the point of maximal hemodynamic compensatory steady state. Similarly, mean arterial pressure decreased from 96 (87, 101) to 60 (53, 78) mmHg (p<0.0001), central venous pressure increased from 4 (4, 5) to 7 (6, 8) mmHg (p<0.0001), heart rate in
Název v anglickém jazyce
Pig Model of Pulmonary Embolism: Where Is the Hemodynamic Break Point?
Popis výsledku anglicky
Early recognition of collapsing hemodynamics in pulmonary embolism is necessary to avoid cardiac arrest using aggressive medical therapy or mechanical cardiac support. The aim of the study was to identify the maximal acute hemodynamic compensatory steadystate. Overall, 40 dynamic obstructions of pulmonary artery were performed and hemodynamic data were collected. Occlusion of only left or right pulmonary artery did not lead to the hemodynamic collapse. When gradually obstructing the bifurcation, the right ventricle end-diastolic area expanded proportionally to pulmonary artery mean pressure from 11.6 (10.1, 14.1) to 17.8 (16.1, 18.8) cm(2) (p<0.0001) and pulmonary artery mean pressure increased from 22 (20, 24) to 44 (41, 47) mmHg (p<0.0001) at the point of maximal hemodynamic compensatory steady state. Similarly, mean arterial pressure decreased from 96 (87, 101) to 60 (53, 78) mmHg (p<0.0001), central venous pressure increased from 4 (4, 5) to 7 (6, 8) mmHg (p<0.0001), heart rate in
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
—
Svazek periodika
62
Číslo periodika v rámci svazku
Suppl. 1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
"S173"-"S179"
Kód UT WoS článku
000328901900019
EID výsledku v databázi Scopus
—