Is intraoperative diffusion tensor imaging at 3.0T comparable to subcortical corticospinal tract mapping?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F13%3A10193717" target="_blank" >RIV/00216208:11110/13:10193717 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985823:_____/13:00397590 RIV/61383082:_____/13:0018
Výsledek na webu
<a href="http://dx.doi.org/10.1227/NEU.0000000000000087" target="_blank" >http://dx.doi.org/10.1227/NEU.0000000000000087</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1227/NEU.0000000000000087" target="_blank" >10.1227/NEU.0000000000000087</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Is intraoperative diffusion tensor imaging at 3.0T comparable to subcortical corticospinal tract mapping?
Popis výsledku v původním jazyce
Primary brain tumors in motor eloquent areas are associated with high-risk surgical procedures because of potentially permanent and often disabling motor deficits. Intraoperative primary motor cortex mapping and corticospinal tract (CST) monitoring are well-developed and reliable techniques. Imaging of the CST by diffusion tensor tractography (DTT) is also feasible. OBJECTIVE: To evaluate the practical value of 3.0T intraoperative MRI (iMRI) with intraoperative DTT (iDTT) in surgery close to the CST, and to compare high-field iDTT with intraoperative neurophysiological CST mapping during glioma and metastasis resection in a routine setting.
Název v anglickém jazyce
Is intraoperative diffusion tensor imaging at 3.0T comparable to subcortical corticospinal tract mapping?
Popis výsledku anglicky
Primary brain tumors in motor eloquent areas are associated with high-risk surgical procedures because of potentially permanent and often disabling motor deficits. Intraoperative primary motor cortex mapping and corticospinal tract (CST) monitoring are well-developed and reliable techniques. Imaging of the CST by diffusion tensor tractography (DTT) is also feasible. OBJECTIVE: To evaluate the practical value of 3.0T intraoperative MRI (iMRI) with intraoperative DTT (iDTT) in surgery close to the CST, and to compare high-field iDTT with intraoperative neurophysiological CST mapping during glioma and metastasis resection in a routine setting.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT12253" target="_blank" >NT12253: Přesnost a přínos MR traktografie v porovnání s kortikální a subkortikální stimulací</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Neurosurgery
ISSN
0148-396X
e-ISSN
—
Svazek periodika
73
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10