Analysis of human blood plasma and hen egg white by chiroptical spectroscopic methods (ECD, VCD, ROA)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F13%3A10196294" target="_blank" >RIV/00216208:11110/13:10196294 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22340/13:43895054 RIV/00064165:_____/13:10196294
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00216-013-6946-6" target="_blank" >http://dx.doi.org/10.1007/s00216-013-6946-6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00216-013-6946-6" target="_blank" >10.1007/s00216-013-6946-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of human blood plasma and hen egg white by chiroptical spectroscopic methods (ECD, VCD, ROA)
Popis výsledku v původním jazyce
Chiroptical methods are widely used in structural and conformational analyses of biopolymers. The application of these methods to investigations of biofluids would provide new avenues for the molecular diagnosis of protein-misfolding diseases. In this work, samples of human blood plasma and hen egg white were analyzed using a combination of conventional and chiroptical methods: ultraviolet absorption/electronic circular dichroism (UV/ECD), Fourier transform infrared absorption/vibrational circular dichroism (FTIR/VCD), and Raman scattering/Raman optical activity (Raman/ROA). For comparison, the main components of these substances-human serum albumin (HSA) and ovalbumin (Ova)-were also analyzed by these methods. The ultraviolet region of the ECD spectrum was analyzed using the CDNN CD software package to evaluate the secondary structures of the proteins. The UV/ECD, FTIR/VCD, and Raman/ROA spectra of the substances were quite similar to those of the corresponding major proteins, while s
Název v anglickém jazyce
Analysis of human blood plasma and hen egg white by chiroptical spectroscopic methods (ECD, VCD, ROA)
Popis výsledku anglicky
Chiroptical methods are widely used in structural and conformational analyses of biopolymers. The application of these methods to investigations of biofluids would provide new avenues for the molecular diagnosis of protein-misfolding diseases. In this work, samples of human blood plasma and hen egg white were analyzed using a combination of conventional and chiroptical methods: ultraviolet absorption/electronic circular dichroism (UV/ECD), Fourier transform infrared absorption/vibrational circular dichroism (FTIR/VCD), and Raman scattering/Raman optical activity (Raman/ROA). For comparison, the main components of these substances-human serum albumin (HSA) and ovalbumin (Ova)-were also analyzed by these methods. The ultraviolet region of the ECD spectrum was analyzed using the CDNN CD software package to evaluate the secondary structures of the proteins. The UV/ECD, FTIR/VCD, and Raman/ROA spectra of the substances were quite similar to those of the corresponding major proteins, while s
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
—
Svazek periodika
405
Číslo periodika v rámci svazku
16
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
13
Strana od-do
5441-5453
Kód UT WoS článku
000319745700009
EID výsledku v databázi Scopus
—