Optimizing the pacing site in the ventricular septum by fluoroscopy and morphology of the paced QRS complex
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F13%3A10210240" target="_blank" >RIV/00216208:11110/13:10210240 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/13:00068363
Výsledek na webu
<a href="http://dx.doi.org/10.5507/bp.2011.063" target="_blank" >http://dx.doi.org/10.5507/bp.2011.063</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2011.063" target="_blank" >10.5507/bp.2011.063</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimizing the pacing site in the ventricular septum by fluoroscopy and morphology of the paced QRS complex
Popis výsledku v původním jazyce
Aims. To analyze the paced QRS duration in various septal positions of the right ventricular leads and with different paced QRS vectors. To use the results to assess parameters suggesting the optimal site for right ventricular pacing. Methods and Results. A total of 609 patients with leads implanted in the right ventricular septum were classified using fluoroscopy in the lateral view (the primary pacing site), and in the anteroposterior view (the secondary pacing site), according to the QRS vector in leads I and III. Significantly shortened paced QRS was found in the primary pacing site with the true septal compared with the anteroseptal site, with the vector being negative or isoelectric in lead I plus positive in lead III. In secondary pacing sites,no significant difference in pacing QRS duration was found between RVOT-HS, RVOT-LS, mid-septum and inferior-septum. Conclusions. For optimization of the pacing site in the ventricular septum, the following are significant: the primary si
Název v anglickém jazyce
Optimizing the pacing site in the ventricular septum by fluoroscopy and morphology of the paced QRS complex
Popis výsledku anglicky
Aims. To analyze the paced QRS duration in various septal positions of the right ventricular leads and with different paced QRS vectors. To use the results to assess parameters suggesting the optimal site for right ventricular pacing. Methods and Results. A total of 609 patients with leads implanted in the right ventricular septum were classified using fluoroscopy in the lateral view (the primary pacing site), and in the anteroposterior view (the secondary pacing site), according to the QRS vector in leads I and III. Significantly shortened paced QRS was found in the primary pacing site with the true septal compared with the anteroseptal site, with the vector being negative or isoelectric in lead I plus positive in lead III. In secondary pacing sites,no significant difference in pacing QRS duration was found between RVOT-HS, RVOT-LS, mid-septum and inferior-septum. Conclusions. For optimization of the pacing site in the ventricular septum, the following are significant: the primary si
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FE - Ostatní obory vnitřního lékařství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Papers
ISSN
1213-8118
e-ISSN
—
Svazek periodika
157
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
56-63
Kód UT WoS článku
000316989100010
EID výsledku v databázi Scopus
—