The scapular glenopolar angle: standard values and side differences
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F14%3A10282298" target="_blank" >RIV/00216208:11110/14:10282298 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61383082:_____/14:#0000278
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00256-014-1977-4" target="_blank" >http://dx.doi.org/10.1007/s00256-014-1977-4</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00256-014-1977-4" target="_blank" >10.1007/s00256-014-1977-4</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The scapular glenopolar angle: standard values and side differences
Popis výsledku v původním jazyce
The aim of this study is to determine normal glenopolar angle (GPA) values on bone specimens of the scapula and compare them with various radiological views and CT examination. GPA values were measured on 100 mature, dry, non-paired scapulae, 20 pairs ofdry scapulae, 50 AP radiographs of the shoulder, 50 Neer I views, 50 AP chest radiographs and 20 3D CT reconstructions of the scapula. Measurements made on bone specimens of the scapula showed an average GPA value of 42.3 A degrees; the mean absolute side-to-side difference was on average 1.6 A degrees. The average GPA measured on 50 AP shoulder radiographs was 35.9 A degrees, on Neer I views 40.6 A degrees and AP chest radiographs 37.1 A degrees, with the mean absolute side-to-side difference on average 4.9 A degrees; on 3D CT the average GPA was 43.0 A degrees and the mean absolute side-to-side difference on average 1.4 A degrees. GPA values depend on the method of measurement used. Measurements made on 3D CT reconstructions and Neer
Název v anglickém jazyce
The scapular glenopolar angle: standard values and side differences
Popis výsledku anglicky
The aim of this study is to determine normal glenopolar angle (GPA) values on bone specimens of the scapula and compare them with various radiological views and CT examination. GPA values were measured on 100 mature, dry, non-paired scapulae, 20 pairs ofdry scapulae, 50 AP radiographs of the shoulder, 50 Neer I views, 50 AP chest radiographs and 20 3D CT reconstructions of the scapula. Measurements made on bone specimens of the scapula showed an average GPA value of 42.3 A degrees; the mean absolute side-to-side difference was on average 1.6 A degrees. The average GPA measured on 50 AP shoulder radiographs was 35.9 A degrees, on Neer I views 40.6 A degrees and AP chest radiographs 37.1 A degrees, with the mean absolute side-to-side difference on average 4.9 A degrees; on 3D CT the average GPA was 43.0 A degrees and the mean absolute side-to-side difference on average 1.4 A degrees. GPA values depend on the method of measurement used. Measurements made on 3D CT reconstructions and Neer
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT14092" target="_blank" >NT14092: Diagnostika a operační léčba dislokovaných nitrokloubních zlomenin lopatky</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Skeletal Radiology
ISSN
0364-2348
e-ISSN
—
Svazek periodika
43
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
1583-1587
Kód UT WoS článku
000342470100010
EID výsledku v databázi Scopus
—