Reference intervals for thyroid markers in early pregnancy determined by 7 different analytical systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F14%3A10284098" target="_blank" >RIV/00216208:11110/14:10284098 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17110/14:A1501DV1 RIV/00843989:_____/14:E0104319 RIV/00064165:_____/14:10284098
Výsledek na webu
<a href="http://dx.doi.org/10.3109/00365513.2013.860617" target="_blank" >http://dx.doi.org/10.3109/00365513.2013.860617</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3109/00365513.2013.860617" target="_blank" >10.3109/00365513.2013.860617</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reference intervals for thyroid markers in early pregnancy determined by 7 different analytical systems
Popis výsledku v původním jazyce
The aim of the study was to verify differences between reference intervals for thyroid-stimulating hormone (TSH) and free thyroxine (FT4), as well as the cut-off for anti-thyroid peroxidase antibodies (TPO Ab) in pregnant women. Additionally, to comparethese reference intervals with those recommended by the manufacturers for a healthy population. Levels of TSH, FT4, and TPO Ab were determined in a group of pregnant women (n = 216) with no history of thyroid dysfunction. Simultaneously, reference intervals for thyroid function tests were established with 7 different analytical systems representing those immunoassays most often used globally. The reference intervals for FT4 were slightly different, according to the system used by each manufacturer. Those for Architect, Centaur, Modular E170, and RIA Immunotech were slightly higher than those for Immulite 2500 and AIA 2000; the lowest being for UniCel DxI (8.13-13.2 pmol/L). For TSH, a higher interval (0.25-3.86 mU/L) is recommended for
Název v anglickém jazyce
Reference intervals for thyroid markers in early pregnancy determined by 7 different analytical systems
Popis výsledku anglicky
The aim of the study was to verify differences between reference intervals for thyroid-stimulating hormone (TSH) and free thyroxine (FT4), as well as the cut-off for anti-thyroid peroxidase antibodies (TPO Ab) in pregnant women. Additionally, to comparethese reference intervals with those recommended by the manufacturers for a healthy population. Levels of TSH, FT4, and TPO Ab were determined in a group of pregnant women (n = 216) with no history of thyroid dysfunction. Simultaneously, reference intervals for thyroid function tests were established with 7 different analytical systems representing those immunoassays most often used globally. The reference intervals for FT4 were slightly different, according to the system used by each manufacturer. Those for Architect, Centaur, Modular E170, and RIA Immunotech were slightly higher than those for Immulite 2500 and AIA 2000; the lowest being for UniCel DxI (8.13-13.2 pmol/L). For TSH, a higher interval (0.25-3.86 mU/L) is recommended for
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT11277" target="_blank" >NT11277: Standardizace diagnostických přístupů hypokortikalismu</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scandinavian Journal of Clinical and Laboratory Investigation
ISSN
0036-5513
e-ISSN
—
Svazek periodika
74
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
NO - Norské království
Počet stran výsledku
7
Strana od-do
95-101
Kód UT WoS článku
000334737700003
EID výsledku v databázi Scopus
—