Ultrasound definition of tendon damage in patients with rheumatoid arthritis. Results of a OMERACT consensus-based ultrasound score focussing on the diagnostic reliability
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F14%3A10285329" target="_blank" >RIV/00216208:11110/14:10285329 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60456540:_____/14:#0000692 RIV/00023728:_____/14:#0004088
Výsledek na webu
<a href="http://dx.doi.org/10.1136/annrheumdis-2013-203596" target="_blank" >http://dx.doi.org/10.1136/annrheumdis-2013-203596</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1136/annrheumdis-2013-203596" target="_blank" >10.1136/annrheumdis-2013-203596</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ultrasound definition of tendon damage in patients with rheumatoid arthritis. Results of a OMERACT consensus-based ultrasound score focussing on the diagnostic reliability
Popis výsledku v původním jazyce
The article presents a new ultrasound scoring system in tendon damage in patients with rheumatoid arthritis. This work has been done on behalf of OMERACT Ultrasound Subtask Group. First, a definition of tendon damage in ultrasound picture was defined andthis definition was accepted among 35 experts in ultrasonography. A questionnaire-method and Delphi method was used. Then, a scoring system was suggested and accepted. Finally, this scoring system was tested for the intraobserver and intraobserver reliability according OMERACT methodology. Intraobserver and interobserver agreement was very good to excellent. This new scoring system has 3 grades: 0-2, where 0 is no damage, 1 means partial rupture and 2- complete rupture of the tendon. The scoring systemdefinition was published including an atlas of pathologies in online version.
Název v anglickém jazyce
Ultrasound definition of tendon damage in patients with rheumatoid arthritis. Results of a OMERACT consensus-based ultrasound score focussing on the diagnostic reliability
Popis výsledku anglicky
The article presents a new ultrasound scoring system in tendon damage in patients with rheumatoid arthritis. This work has been done on behalf of OMERACT Ultrasound Subtask Group. First, a definition of tendon damage in ultrasound picture was defined andthis definition was accepted among 35 experts in ultrasonography. A questionnaire-method and Delphi method was used. Then, a scoring system was suggested and accepted. Finally, this scoring system was tested for the intraobserver and intraobserver reliability according OMERACT methodology. Intraobserver and interobserver agreement was very good to excellent. This new scoring system has 3 grades: 0-2, where 0 is no damage, 1 means partial rupture and 2- complete rupture of the tendon. The scoring systemdefinition was published including an atlas of pathologies in online version.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FE - Ostatní obory vnitřního lékařství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT12437" target="_blank" >NT12437: Optimalizace výsledků biologické léčby revmatoidní artritidy v praxi</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Annals of the Rheumatic Diseases
ISSN
0003-4967
e-ISSN
—
Svazek periodika
73
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
1929-1934
Kód UT WoS článku
000343308200013
EID výsledku v databázi Scopus
—