Popis výsledku v původním jazyce
The aim was to compare methods of body fat measurement in different BMI groups. An additional aim was to discuss differences reflecting the structural and functional changes of fat tissue. The study group included 130 adult Caucasian women stratified bybody mass index (BMI): 18-24.99 (n=30), 25-29.99 (n=26), 30-34.99 (n=33), 35-39.99 (n=30), and BMI }= 40 (n=11). Bioelectrical impedance was performed using Tanita TBF 410 GS, Bodystat 1500, and Omron BF 300. A caliper type Best was also applied. Correspondence of four methods with DEXA was assessed using the Bland-Altman and ANOVA analyses. Measurements by BIA were not significantly different from DEXA up to BMI of 30, but DEXA significantly overestimated in the higher BMI subgroup by all three methods. Caliper measurement significantly underestimated DEXA in all BMI subgroups. BIA methods overestimated DEXA for the obese subjects. Tanita did statistically the best. The Caliper test appeared less preferable than the BIA methods, especi
Název v anglickém jazyce
Does Impedance Measure a Functional State of the Body Fat?
Popis výsledku anglicky
The aim was to compare methods of body fat measurement in different BMI groups. An additional aim was to discuss differences reflecting the structural and functional changes of fat tissue. The study group included 130 adult Caucasian women stratified bybody mass index (BMI): 18-24.99 (n=30), 25-29.99 (n=26), 30-34.99 (n=33), 35-39.99 (n=30), and BMI }= 40 (n=11). Bioelectrical impedance was performed using Tanita TBF 410 GS, Bodystat 1500, and Omron BF 300. A caliper type Best was also applied. Correspondence of four methods with DEXA was assessed using the Bland-Altman and ANOVA analyses. Measurements by BIA were not significantly different from DEXA up to BMI of 30, but DEXA significantly overestimated in the higher BMI subgroup by all three methods. Caliper measurement significantly underestimated DEXA in all BMI subgroups. BIA methods overestimated DEXA for the obese subjects. Tanita did statistically the best. The Caliper test appeared less preferable than the BIA methods, especi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FB - Endokrinologie, diabetologie, metabolismus, výživa
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT14182" target="_blank" >NT14182: Ftaláty a estrogenní endokrinní disruptory ve vztahu k metabolickým onemocněním</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
—
Svazek periodika
63
Číslo periodika v rámci svazku
Suppl. 2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
12
Strana od-do
"S309"-"S320"
Kód UT WoS článku
000345590400008
EID výsledku v databázi Scopus
—