Comparing morbidity and cancer control after 3D-conformal (70/74 Gy) and intensity modulated radiotherapy (78/82 Gy) for prostate cancer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F15%3A10295029" target="_blank" >RIV/00216208:11110/15:10295029 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/15:43909645 RIV/00216275:25520/15:39900944 RIV/00179906:_____/15:10295029
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00066-014-0806-y" target="_blank" >http://dx.doi.org/10.1007/s00066-014-0806-y</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00066-014-0806-y" target="_blank" >10.1007/s00066-014-0806-y</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparing morbidity and cancer control after 3D-conformal (70/74 Gy) and intensity modulated radiotherapy (78/82 Gy) for prostate cancer
Popis výsledku v původním jazyce
Purpose The purpose of this work was to compare toxicity and cancer control between patients with prostate cancer treated using three-dimensional conformal radiotherapy (3D-CRT) and those treated using intensity-modulated radiation therapy (IMRT). Methods and materials A total of 553 patients with prostate cancer were treated with 3D-CRT 70-74 Gy (3D-CRT 70, 3D-CRT 74) or IMRT 78-82 Gy (IMRT 78, IMRT/SIB 82). Late toxicity was scored according to FC-RTOG/LENT criteria. Biochemical failure was defined using the Phoenix and ASTRO definitions. Results The 5-year risk of grade 2-4 genitourinary toxicity was 26.3 % (3D-CRT 70), 27.2 % (3D-CRT 74), 17.3 % (IMRT 78), and 25.1 % (IMRT/SIB 82) without statistical differences. The 5-year risk of grade 2-4 gastrointestinal toxicity was 19.4 % (3D-CRT 70), 42.1 % (3D-CRT 74), 20.5 % (IMRT 78), and 26.6 % (IMRT/SIB 82). The differences between 3D-CRT 74 and 3D-CRT 70 and between 3D-CRT 74 and IMRT 78 were statistically significant (log rank p = 0.0
Název v anglickém jazyce
Comparing morbidity and cancer control after 3D-conformal (70/74 Gy) and intensity modulated radiotherapy (78/82 Gy) for prostate cancer
Popis výsledku anglicky
Purpose The purpose of this work was to compare toxicity and cancer control between patients with prostate cancer treated using three-dimensional conformal radiotherapy (3D-CRT) and those treated using intensity-modulated radiation therapy (IMRT). Methods and materials A total of 553 patients with prostate cancer were treated with 3D-CRT 70-74 Gy (3D-CRT 70, 3D-CRT 74) or IMRT 78-82 Gy (IMRT 78, IMRT/SIB 82). Late toxicity was scored according to FC-RTOG/LENT criteria. Biochemical failure was defined using the Phoenix and ASTRO definitions. Results The 5-year risk of grade 2-4 genitourinary toxicity was 26.3 % (3D-CRT 70), 27.2 % (3D-CRT 74), 17.3 % (IMRT 78), and 25.1 % (IMRT/SIB 82) without statistical differences. The 5-year risk of grade 2-4 gastrointestinal toxicity was 19.4 % (3D-CRT 70), 42.1 % (3D-CRT 74), 20.5 % (IMRT 78), and 26.6 % (IMRT/SIB 82). The differences between 3D-CRT 74 and 3D-CRT 70 and between 3D-CRT 74 and IMRT 78 were statistically significant (log rank p = 0.0
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Strahlentherapie und Onkologie
ISSN
0179-7158
e-ISSN
—
Svazek periodika
191
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
9
Strana od-do
338-346
Kód UT WoS článku
000353219300006
EID výsledku v databázi Scopus
2-s2.0-84933525368