Improved specimen adequacy using jumbo biopsy forceps in patients with Barrett's esophagus
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F15%3A10296368" target="_blank" >RIV/00216208:11110/15:10296368 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61383082:_____/15:#0000390 RIV/00023001:_____/15:00059348
Výsledek na webu
<a href="http://dx.doi.org/10.3748/wjg.v21.i17.5328" target="_blank" >http://dx.doi.org/10.3748/wjg.v21.i17.5328</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3748/wjg.v21.i17.5328" target="_blank" >10.3748/wjg.v21.i17.5328</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improved specimen adequacy using jumbo biopsy forceps in patients with Barrett's esophagus
Popis výsledku v původním jazyce
AIM: To assess the sampling quality of four different forceps (three large capacity and one jumbo) in patients with Barrett's esophagus. METHODS: This was a prospective, single-blind study. A total of 37 patients with Barrett's esophagus were enrolled. Targeted or random biopsies with all four forceps were obtained from each patient using a diagnostic endoscope during a single endoscopy. The following forceps were tested: A: FB-220K disposable large capacity; B: BI01-D3-23 reusable large capacity; C: GBF-02-23-180 disposable large capacity; and jumbo: disposable Radial Jaw 4 jumbo. The primary outcome measurement was specimen adequacy, defined as a well-oriented biopsy sample 2 mm or greater with the presence of muscularis mucosa. RESULTS: A total of 436 biopsy samples were analyzed. We found a significantly higher proportion of adequate biopsy samples with jumbo forceps (71%) (P < 0.001 vs forceps A: 26%, forceps B: 17%, and forceps C: 18%). Biopsies with jumbo forceps had the largest
Název v anglickém jazyce
Improved specimen adequacy using jumbo biopsy forceps in patients with Barrett's esophagus
Popis výsledku anglicky
AIM: To assess the sampling quality of four different forceps (three large capacity and one jumbo) in patients with Barrett's esophagus. METHODS: This was a prospective, single-blind study. A total of 37 patients with Barrett's esophagus were enrolled. Targeted or random biopsies with all four forceps were obtained from each patient using a diagnostic endoscope during a single endoscopy. The following forceps were tested: A: FB-220K disposable large capacity; B: BI01-D3-23 reusable large capacity; C: GBF-02-23-180 disposable large capacity; and jumbo: disposable Radial Jaw 4 jumbo. The primary outcome measurement was specimen adequacy, defined as a well-oriented biopsy sample 2 mm or greater with the presence of muscularis mucosa. RESULTS: A total of 436 biopsy samples were analyzed. We found a significantly higher proportion of adequate biopsy samples with jumbo forceps (71%) (P < 0.001 vs forceps A: 26%, forceps B: 17%, and forceps C: 18%). Biopsies with jumbo forceps had the largest
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FE - Ostatní obory vnitřního lékařství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT13636" target="_blank" >NT13636: BARRETTŮV JÍCEN : ENDOSKOPICKÁ LÉČBA vs. OBSERVACE PACIENTŮ S NÍZKÝM STUPNĚM DYSPLÁZIE</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
World Journal of Gastroenterology
ISSN
1007-9327
e-ISSN
—
Svazek periodika
21
Číslo periodika v rámci svazku
17
Stát vydavatele periodika
CN - Čínská lidová republika
Počet stran výsledku
8
Strana od-do
5328-5335
Kód UT WoS článku
000353774100024
EID výsledku v databázi Scopus
2-s2.0-84928990307