Can the Gold Standard Be Beaten? How Reliable Are Various Modifications of the Synacthen Test Compared to the Insulin Tolerance Test
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F17%3A10363748" target="_blank" >RIV/00216208:11110/17:10363748 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/17:43915708 RIV/00023761:_____/17:N0000038 RIV/00064173:_____/17:N0000112 RIV/00064165:_____/17:10363748
Výsledek na webu
<a href="http://www.biomed.cas.cz/physiolres/pdf/66/66_S387.pdf" target="_blank" >http://www.biomed.cas.cz/physiolres/pdf/66/66_S387.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Can the Gold Standard Be Beaten? How Reliable Are Various Modifications of the Synacthen Test Compared to the Insulin Tolerance Test
Popis výsledku v původním jazyce
Criteria for the evaluation of the insulin tolerance test (ITT) and Synacthen test are still a matter of debate. The objective of the study was to make a comparison of serum and salivary cortisol during four stimulation tests. Sixty four healthy volunteers underwent the ITT, the Synacthen test with 1 (LDST), 10 (MDST) and 250 (HDST)μg dose of ACTH. Maximum serum cortisol response was observed at the 90 min of the ITT (49 %), HDST(89 %) and MDST (56 %) and at the 40 min of the LDST (44 %). Results expressed as 95 % confidence intervals: 408.0-843.6 and 289.5-868.1 nmol/l in the IIT at 60 and 90 min. In the HDST and the MDST serum cortisol reached the maximum at 90 min 542.6- 1245.5 and 444.2-871.3 nmol/l. Levels of salivary cortisol followed the same pattern as serum cortisol. Salivary cortisol reached the maximum response in the HDST and the MDST at 90 min and at 40 min in the LDST. We confirmed good reliability of all tests with respect to timing of response and maximum response compared to the ITT. We proved that the MDST test can provide the similar response in serum cortisol to the HDST. Measuring either salivary cortisol or ACTH levels did not provide any additional benefit then measuring serum cortisol by itself.
Název v anglickém jazyce
Can the Gold Standard Be Beaten? How Reliable Are Various Modifications of the Synacthen Test Compared to the Insulin Tolerance Test
Popis výsledku anglicky
Criteria for the evaluation of the insulin tolerance test (ITT) and Synacthen test are still a matter of debate. The objective of the study was to make a comparison of serum and salivary cortisol during four stimulation tests. Sixty four healthy volunteers underwent the ITT, the Synacthen test with 1 (LDST), 10 (MDST) and 250 (HDST)μg dose of ACTH. Maximum serum cortisol response was observed at the 90 min of the ITT (49 %), HDST(89 %) and MDST (56 %) and at the 40 min of the LDST (44 %). Results expressed as 95 % confidence intervals: 408.0-843.6 and 289.5-868.1 nmol/l in the IIT at 60 and 90 min. In the HDST and the MDST serum cortisol reached the maximum at 90 min 542.6- 1245.5 and 444.2-871.3 nmol/l. Levels of salivary cortisol followed the same pattern as serum cortisol. Salivary cortisol reached the maximum response in the HDST and the MDST at 90 min and at 40 min in the LDST. We confirmed good reliability of all tests with respect to timing of response and maximum response compared to the ITT. We proved that the MDST test can provide the similar response in serum cortisol to the HDST. Measuring either salivary cortisol or ACTH levels did not provide any additional benefit then measuring serum cortisol by itself.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30202 - Endocrinology and metabolism (including diabetes, hormones)
Návaznosti výsledku
Projekt
<a href="/cs/project/NT11277" target="_blank" >NT11277: Standardizace diagnostických přístupů hypokortikalismu</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
—
Svazek periodika
66
Číslo periodika v rámci svazku
Suppl. 3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
387-395
Kód UT WoS článku
000412737900013
EID výsledku v databázi Scopus
—