Effect of Pulsatility on Microcirculation in Patients Treated with Extracorporeal Cardiopulmonary Resuscitation: A Pilot Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F17%3A10364447" target="_blank" >RIV/00216208:11110/17:10364447 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21730/17:00320088 RIV/00064203:_____/17:10364447 RIV/00064165:_____/17:10364447
Výsledek na webu
<a href="http://dx.doi.org/10.1097/MAT.0000000000000492" target="_blank" >http://dx.doi.org/10.1097/MAT.0000000000000492</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/MAT.0000000000000492" target="_blank" >10.1097/MAT.0000000000000492</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of Pulsatility on Microcirculation in Patients Treated with Extracorporeal Cardiopulmonary Resuscitation: A Pilot Study
Popis výsledku v původním jazyce
The effect of pulsatile blood flow on microcirculation during extracorporeal cardiopulmonary resuscitation (ECPR) is not elucidated; therefore, we designed an observational study comparing sublingual microcirculation in patients with refractory cardiac arrest (CA) with spontaneously pulsatile or low/nonpulsatile blood flow after treatment with ECPR. Microcirculation was assessed with Sidestream Dark Field technology in 12 patients with CA who were treated with ECPR and 12 healthy control subjects. Microcirculatory images were analyzed offline in a blinded fashion, and consensual parameters were determined for the vessels <= 20 mu m. The patients' data, including actual hemodynamic parameters, were documented. Pulsatile blood flow was defined by a pulse pressure (PP) >= 15 mm Hg. Compared with the healthy volunteers, the patients who were treated with ECPR exhibited a significantly lower proportion of perfused capillaries (PPC); other microcirculatory parameters did not differ. The groups of patients with pulsatile (n = 7) versus low/nonpulsatile (n = 5) blood flow did not differ in regards to the collected data and hemodynamic variables (except for the PP and ejection fraction of the left ventricle) as well as microcirculatory parameters. In conclusion, microcirculation appeared to be effectively supported by ECPR in our group of patients with CA with the exception of the PPC. We found only nonsignificant contribution of spontaneous pulsatility to extracorporeal membrane oxygenation-generated microcirculatory blood flow.
Název v anglickém jazyce
Effect of Pulsatility on Microcirculation in Patients Treated with Extracorporeal Cardiopulmonary Resuscitation: A Pilot Study
Popis výsledku anglicky
The effect of pulsatile blood flow on microcirculation during extracorporeal cardiopulmonary resuscitation (ECPR) is not elucidated; therefore, we designed an observational study comparing sublingual microcirculation in patients with refractory cardiac arrest (CA) with spontaneously pulsatile or low/nonpulsatile blood flow after treatment with ECPR. Microcirculation was assessed with Sidestream Dark Field technology in 12 patients with CA who were treated with ECPR and 12 healthy control subjects. Microcirculatory images were analyzed offline in a blinded fashion, and consensual parameters were determined for the vessels <= 20 mu m. The patients' data, including actual hemodynamic parameters, were documented. Pulsatile blood flow was defined by a pulse pressure (PP) >= 15 mm Hg. Compared with the healthy volunteers, the patients who were treated with ECPR exhibited a significantly lower proportion of perfused capillaries (PPC); other microcirculatory parameters did not differ. The groups of patients with pulsatile (n = 7) versus low/nonpulsatile (n = 5) blood flow did not differ in regards to the collected data and hemodynamic variables (except for the PP and ejection fraction of the left ventricle) as well as microcirculatory parameters. In conclusion, microcirculation appeared to be effectively supported by ECPR in our group of patients with CA with the exception of the PPC. We found only nonsignificant contribution of spontaneous pulsatility to extracorporeal membrane oxygenation-generated microcirculatory blood flow.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/NT13225" target="_blank" >NT13225: Hyperinvazívní přístup k mimonemocniční zástavě srdce s použitím mechanizované masáže, přednemocničního chlazení, mimotělní podpory oběhu a časného invazívního vyšetření ve srovnání se standardní péčí. Randomizovaná srovnávací studie. "Prague OHCA study"</a><br>
Návaznosti
O - Projekt operacniho programu
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ASAIO Journal
ISSN
1058-2916
e-ISSN
—
Svazek periodika
63
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
386-391
Kód UT WoS článku
000408848900007
EID výsledku v databázi Scopus
2-s2.0-85021872899