Surgical resection of occluded abdominal stent graft followed by aorto-bi-iliac vascular reconstruction with Intergard Synergy vascular prosthesis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F18%3A10381930" target="_blank" >RIV/00216208:11110/18:10381930 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064165:_____/18:10381930
Výsledek na webu
<a href="https://doi.org/10.1016/j.crvasa.2017.11.003" target="_blank" >https://doi.org/10.1016/j.crvasa.2017.11.003</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.crvasa.2017.11.003" target="_blank" >10.1016/j.crvasa.2017.11.003</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Surgical resection of occluded abdominal stent graft followed by aorto-bi-iliac vascular reconstruction with Intergard Synergy vascular prosthesis
Popis výsledku v původním jazyce
Introduction: We are presenting a case report of an 82 years old polymorbid patient treated with Aortofix AAA Flexible Stent Graft System for symptomatic 51 mm subrenal aortic aneurysm complicated with an early closure of the right stent graft branch resulting in a severe right lower extremity ischemia. Method: Stent graft dissection and resection were performed trough midline laparotomy. Due to the severe calcifications of the supra- and sub-renal aorta, a Nucleus 25 mm balloon was inserted into the abdominal aorta instead of using an aortal cross-clamp. After the resection, aorto-bi-iliac revascularisation was performed with the use of Intergard Synergy 18/ 9 mm vascular prosthesis. Result: Following the stent graft resection and surgical revascularisation, normal blood flow was restored into the affected lower extremity with no residual signs and symptoms of limb ischemia. The patient recovered without any further complications and was discharged on the fifth postoperative day. Conclusion: When endovascular treatments of stent grafts' branch occlusion fail, surgical treatment, despite its higher perioperative risks and technical challenges, remains the only treatment option.
Název v anglickém jazyce
Surgical resection of occluded abdominal stent graft followed by aorto-bi-iliac vascular reconstruction with Intergard Synergy vascular prosthesis
Popis výsledku anglicky
Introduction: We are presenting a case report of an 82 years old polymorbid patient treated with Aortofix AAA Flexible Stent Graft System for symptomatic 51 mm subrenal aortic aneurysm complicated with an early closure of the right stent graft branch resulting in a severe right lower extremity ischemia. Method: Stent graft dissection and resection were performed trough midline laparotomy. Due to the severe calcifications of the supra- and sub-renal aorta, a Nucleus 25 mm balloon was inserted into the abdominal aorta instead of using an aortal cross-clamp. After the resection, aorto-bi-iliac revascularisation was performed with the use of Intergard Synergy 18/ 9 mm vascular prosthesis. Result: Following the stent graft resection and surgical revascularisation, normal blood flow was restored into the affected lower extremity with no residual signs and symptoms of limb ischemia. The patient recovered without any further complications and was discharged on the fifth postoperative day. Conclusion: When endovascular treatments of stent grafts' branch occlusion fail, surgical treatment, despite its higher perioperative risks and technical challenges, remains the only treatment option.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cor et Vasa
ISSN
0010-8650
e-ISSN
—
Svazek periodika
60
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
"e547"-"e550"
Kód UT WoS článku
000446218800025
EID výsledku v databázi Scopus
2-s2.0-85034853232