Assessment of renal function before contrast media injection: right decisions based on inaccurate estimates
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F19%3A10388223" target="_blank" >RIV/00216208:11110/19:10388223 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064165:_____/19:10388223
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=5Jv2cVlcvp" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=5Jv2cVlcvp</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00330-018-5753-z" target="_blank" >10.1007/s00330-018-5753-z</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of renal function before contrast media injection: right decisions based on inaccurate estimates
Popis výsledku v původním jazyce
Objectives: Information on renal function required before specified radiological examinations with contrast agents is usually obtained through prediction equations using serum creatinine and anthropometric data. The aim of our study was to demonstrate discrepancy between poor prediction and good diagnostic accuracy of glomerular filtration rate (GFR) estimated by prediction equations. Methods: In 50 patients, reference GFR was measured as plasma clearance of 51-chromium labeled ethylene-diamine-tetraacetic-acid (51Cr-EDTA) and compared with GFR assayed by creatinine clearance (CC) and estimated by Cockcroft-Gault prediction equation (CG). For comparisons, CC and CG were considered as continuous, categorical, and binary variables. Accuracy of the reference GFR prediction was expressed in terms of prediction errors and diagnostic accuracy indices. Results: As continuous variable, CG estimated individual values of GFR with large prediction error exceeding that of CC. As categorical variable, it classified the patient stage of chronic kidney disease (CKD) with medium diagnostic accuracy of 74% (CKD 3) and 62% (CKD 4). As binary variable, CG classified individual patient's GFR below 30 and 60 ml/min/1.73 m2 with good diagnostic accuracy of 80 and 94%, respectively. Performance of other prediction equations did not significantly differ from CG. Conclusions: Despite large variance and poor prediction accuracy of individual GFR estimates, most of them correctly classified individual patient's GFR below specified level. Results of prediction equations thus should be used and reported exclusively as binary variables, while numerical values of GFR, if required, should be measured by more accurate radionuclide or laboratory methods.
Název v anglickém jazyce
Assessment of renal function before contrast media injection: right decisions based on inaccurate estimates
Popis výsledku anglicky
Objectives: Information on renal function required before specified radiological examinations with contrast agents is usually obtained through prediction equations using serum creatinine and anthropometric data. The aim of our study was to demonstrate discrepancy between poor prediction and good diagnostic accuracy of glomerular filtration rate (GFR) estimated by prediction equations. Methods: In 50 patients, reference GFR was measured as plasma clearance of 51-chromium labeled ethylene-diamine-tetraacetic-acid (51Cr-EDTA) and compared with GFR assayed by creatinine clearance (CC) and estimated by Cockcroft-Gault prediction equation (CG). For comparisons, CC and CG were considered as continuous, categorical, and binary variables. Accuracy of the reference GFR prediction was expressed in terms of prediction errors and diagnostic accuracy indices. Results: As continuous variable, CG estimated individual values of GFR with large prediction error exceeding that of CC. As categorical variable, it classified the patient stage of chronic kidney disease (CKD) with medium diagnostic accuracy of 74% (CKD 3) and 62% (CKD 4). As binary variable, CG classified individual patient's GFR below 30 and 60 ml/min/1.73 m2 with good diagnostic accuracy of 80 and 94%, respectively. Performance of other prediction equations did not significantly differ from CG. Conclusions: Despite large variance and poor prediction accuracy of individual GFR estimates, most of them correctly classified individual patient's GFR below specified level. Results of prediction equations thus should be used and reported exclusively as binary variables, while numerical values of GFR, if required, should be measured by more accurate radionuclide or laboratory methods.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
<a href="/cs/project/GA303%2F07%2F0950" target="_blank" >GA303/07/0950: Kvantitativní hodnocení dynamické scintigrafie ledvin</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Radiology
ISSN
0938-7994
e-ISSN
—
Svazek periodika
29
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
3192-3199
Kód UT WoS článku
000467646300047
EID výsledku v databázi Scopus
2-s2.0-85056335288