Load-carrying capacity of short implants in edentulous posterior maxilla: A finite element study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F19%3A10409969" target="_blank" >RIV/00216208:11110/19:10409969 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Ho2sV22LKw" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Ho2sV22LKw</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.medengphy.2019.02.003" target="_blank" >10.1016/j.medengphy.2019.02.003</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Load-carrying capacity of short implants in edentulous posterior maxilla: A finite element study
Popis výsledku v původním jazyce
Dental implant dimensions, and bone quality and quantity play a key role in early osseointegration and long-term prognosis in posterior edentulous maxilla. Treatment with short implants, preferably in a bicortical manner, is an accepted modality; however, short implants have limitations leading to increased stress concentrations in alveolar bone, potential overload and implant failure. Implant models of 3.3, 4.1, 4.8 and 5.4 mm diameter and 4.5, 5.5, 6.5, 7.5 and 8.5 mm length were placed in posterior maxilla 3-D models with corresponding residual bone heights. Bone-implant assemblies were analyzed in finite element software ANSYS 15. All materials were assumed to be linearly elastic and isotropic. 118.2N oblique loading was applied to investigate stress distributions in bone tissues. The concept of ultimate functional load (UFL) was selected as a criterion to compare load-carrying capacity of implants and to evaluate the influence of available bone height and implant dimensions on load-carrying capacity. For all implants, UFL was calculated by limiting von Mises stresses in cortical or cancellous bone with bone strength (100 MPa for cortical and 2 MPa for cancellous bone). Implant load-carrying capacity depends on diameter and available bone height. Wide implants have higher load-carrying capacity than narrow implants. Short implants with proper diameter and length avoid bone overstress, even in Type IV bone.
Název v anglickém jazyce
Load-carrying capacity of short implants in edentulous posterior maxilla: A finite element study
Popis výsledku anglicky
Dental implant dimensions, and bone quality and quantity play a key role in early osseointegration and long-term prognosis in posterior edentulous maxilla. Treatment with short implants, preferably in a bicortical manner, is an accepted modality; however, short implants have limitations leading to increased stress concentrations in alveolar bone, potential overload and implant failure. Implant models of 3.3, 4.1, 4.8 and 5.4 mm diameter and 4.5, 5.5, 6.5, 7.5 and 8.5 mm length were placed in posterior maxilla 3-D models with corresponding residual bone heights. Bone-implant assemblies were analyzed in finite element software ANSYS 15. All materials were assumed to be linearly elastic and isotropic. 118.2N oblique loading was applied to investigate stress distributions in bone tissues. The concept of ultimate functional load (UFL) was selected as a criterion to compare load-carrying capacity of implants and to evaluate the influence of available bone height and implant dimensions on load-carrying capacity. For all implants, UFL was calculated by limiting von Mises stresses in cortical or cancellous bone with bone strength (100 MPa for cortical and 2 MPa for cancellous bone). Implant load-carrying capacity depends on diameter and available bone height. Wide implants have higher load-carrying capacity than narrow implants. Short implants with proper diameter and length avoid bone overstress, even in Type IV bone.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30208 - Dentistry, oral surgery and medicine
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Medical Engineering & Physics
ISSN
1350-4533
e-ISSN
—
Svazek periodika
71
Číslo periodika v rámci svazku
September
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
30-37
Kód UT WoS článku
000519206700006
EID výsledku v databázi Scopus
2-s2.0-85068410047