Glycemic Outcomes in Adults With T1D Are Impacted More by Continuous Glucose Monitoring Than by Insulin Delivery Method: 3 Years of Follow-Up From the COMISAIR Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10407472" target="_blank" >RIV/00216208:11110/20:10407472 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/20:10407472 RIV/00064203:_____/20:10407472 RIV/00064165:_____/20:10407472
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=P2S1zNqHpC" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=P2S1zNqHpC</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2337/dc19-0888" target="_blank" >10.2337/dc19-0888</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Glycemic Outcomes in Adults With T1D Are Impacted More by Continuous Glucose Monitoring Than by Insulin Delivery Method: 3 Years of Follow-Up From the COMISAIR Study
Popis výsledku v původním jazyce
OBJECTIVE This study assessed the clinical impact of four treatment strategies in adults with type 1 diabetes (T1D): real-time continuous glucose monitoring (rtCGM) with multiple daily insulin injections (rtCGM+MDI), rtCGM with continuous subcutaneous insulin infusion (rtCGM+CSII), self-monitoring of blood glucose with MDI (SMBG+MDI), and SMBG with CSII (SMBG+CSII). RESEARCH DESIGN AND METHODS This 3-year, nonrandomized, prospective, real-world, clinical trial followed 94 participants with T1D (rtCGM+MDI, n = 22; rtCGM+CSII, n = 26; SMBG+MDI, n = 21; SMBG+CSII, n = 25). The main end points were changes in A1C, time in range (70-180 mg/dL [3.9-10 mmol/L]), time below range (<70 mg/dL [<3.9 mmol/L]), glycemic variability, and incidence of hypoglycemia. RESULTS At 3 years, the rtCGM groups (rtCGM+MDI and rtCGM+CSII) had significantly lower A1C (7.0% [53 mmol/mol], P = 0.0002, and 6.9% [52 mmol/mol], P < 0.0001, respectively), compared with the SMBG+CSII and SMBG+MDI groups (7.7% [61 mmol/mol], P = 0.3574, and 8.0% [64 mmol/mol], P = 1.000, respectively), with no significant difference between the rtCGM groups. Significant improvements in percentage of time in range were observed in the rtCGM subgroups (rtCGM+MDI, 48.7-69.0%, P < 0.0001; and rtCGM+CSII, 50.9-72.3%, P < 0.0001) and in the SMBG+CSII group (50.6-57.8%, P = 0.0114). Significant reductions in time below range were found only in the rtCGM subgroups (rtCGM+MDI, 9.4-5.5%, P = 0.0387; and rtCGM+CSII, 9.0-5.3%, P = 0.0235). Seven severe hypoglycemia episodes occurred: SMBG groups, n = 5; sensor-augmented insulin regimen groups, n = 2. CONCLUSIONS rtCGM was superior to SMBG in reducing A1C, hypoglycemia, and other end points in individuals with T1D regardless of their insulin delivery method. rtCGM+MDI can be considered an equivalent but lower-cost alternative to sensor-augmented insulin pump therapy and superior to treatment with SMBG+MDI or SMBG+CSII therapy.
Název v anglickém jazyce
Glycemic Outcomes in Adults With T1D Are Impacted More by Continuous Glucose Monitoring Than by Insulin Delivery Method: 3 Years of Follow-Up From the COMISAIR Study
Popis výsledku anglicky
OBJECTIVE This study assessed the clinical impact of four treatment strategies in adults with type 1 diabetes (T1D): real-time continuous glucose monitoring (rtCGM) with multiple daily insulin injections (rtCGM+MDI), rtCGM with continuous subcutaneous insulin infusion (rtCGM+CSII), self-monitoring of blood glucose with MDI (SMBG+MDI), and SMBG with CSII (SMBG+CSII). RESEARCH DESIGN AND METHODS This 3-year, nonrandomized, prospective, real-world, clinical trial followed 94 participants with T1D (rtCGM+MDI, n = 22; rtCGM+CSII, n = 26; SMBG+MDI, n = 21; SMBG+CSII, n = 25). The main end points were changes in A1C, time in range (70-180 mg/dL [3.9-10 mmol/L]), time below range (<70 mg/dL [<3.9 mmol/L]), glycemic variability, and incidence of hypoglycemia. RESULTS At 3 years, the rtCGM groups (rtCGM+MDI and rtCGM+CSII) had significantly lower A1C (7.0% [53 mmol/mol], P = 0.0002, and 6.9% [52 mmol/mol], P < 0.0001, respectively), compared with the SMBG+CSII and SMBG+MDI groups (7.7% [61 mmol/mol], P = 0.3574, and 8.0% [64 mmol/mol], P = 1.000, respectively), with no significant difference between the rtCGM groups. Significant improvements in percentage of time in range were observed in the rtCGM subgroups (rtCGM+MDI, 48.7-69.0%, P < 0.0001; and rtCGM+CSII, 50.9-72.3%, P < 0.0001) and in the SMBG+CSII group (50.6-57.8%, P = 0.0114). Significant reductions in time below range were found only in the rtCGM subgroups (rtCGM+MDI, 9.4-5.5%, P = 0.0387; and rtCGM+CSII, 9.0-5.3%, P = 0.0235). Seven severe hypoglycemia episodes occurred: SMBG groups, n = 5; sensor-augmented insulin regimen groups, n = 2. CONCLUSIONS rtCGM was superior to SMBG in reducing A1C, hypoglycemia, and other end points in individuals with T1D regardless of their insulin delivery method. rtCGM+MDI can be considered an equivalent but lower-cost alternative to sensor-augmented insulin pump therapy and superior to treatment with SMBG+MDI or SMBG+CSII therapy.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30202 - Endocrinology and metabolism (including diabetes, hormones)
Návaznosti výsledku
Projekt
<a href="/cs/project/NV15-26705A" target="_blank" >NV15-26705A: Vliv glukózové variability na patogenetické mechanizmy rozvoje cévních změn při diabetu 1. typu</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Diabetes Care
ISSN
0149-5992
e-ISSN
—
Svazek periodika
43
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
37-43
Kód UT WoS článku
000508573600017
EID výsledku v databázi Scopus
2-s2.0-85075539471