Degree of Conversion Contributes to Dentin Bonding Durability of Contemporary Universal Adhesives
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10410622" target="_blank" >RIV/00216208:11110/20:10410622 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=G.Q0e8v1vl" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=G.Q0e8v1vl</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2341/19-165-L" target="_blank" >10.2341/19-165-L</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Degree of Conversion Contributes to Dentin Bonding Durability of Contemporary Universal Adhesives
Popis výsledku v původním jazyce
PURPOSE: The objectives of this study were to evaluate the micro-tensile bond strength (μTBS) of five contemporary universal adhesives to dentin after 24 hours and thermocycling (TC), to measure their degrees of conversion (DC) and to test the correlation between μTBS and DC. METHODS AND MATERIALS: Four commercially available universal adhesives, Prime&Bond universal (PBU), Ecosite Bond (EB), G-Premio Bond (GPB), and Clearfil Universal Bond Quick (UBQ), and one experimental adhesive, UBQ without an amide monomer (UBQ-A), were used in this study. For the μTBS test, midcoronal dentin of 50 human molars was exposed, ground using 600-grit SiC paper, and the adhesives were applied according to the manufacturers' instructions. After resin-composite buildup and 24-hour water storage, one-half of the specimens were subjected to 15,000 thermal cycles. The specimens were sectioned into beams and stressed in tension at a crosshead speed of 1 mm/min until failure. The DC of adhesives applied to dentin was evaluated using attenuated total reflectance Fourier-transform infrared spectroscopy immediately after light-curing. All data were statistically analyzed at a significance level of 0.05. RESULTS: The highest μTBSs were obtained with UBQ, UBQ-A, and PBU, which were not significantly different from each other both after 24 hours and TC. The μTBS of GPB was lower compared with the aforementioned adhesives, but significantly only after TC, and the lowest μTBSs were obtained with EB. TC did not affect the μTBSs of UBQ, UBQ-A, and PBU significantly, but a significant decrease was observed with GPB and EB. The highest DC was obtained with PBU and UBQ, followed by 2-hydroxyethyl methacrylate-rich adhesives UBQ-A and EB, which exhibited significantly lower DCs. The DC of GPB could not be determined because the reference peak at 1608 cm-1 was not detected in its spectra. A significant positive correlation was shown between μTBS and DC after 24 hours (r=0.716) and TC (r=0.856). CONCLUSION: μTBS and DC were positively correlated, more markedly after TC, which suggests that DC may be an important factor for bond durability.
Název v anglickém jazyce
Degree of Conversion Contributes to Dentin Bonding Durability of Contemporary Universal Adhesives
Popis výsledku anglicky
PURPOSE: The objectives of this study were to evaluate the micro-tensile bond strength (μTBS) of five contemporary universal adhesives to dentin after 24 hours and thermocycling (TC), to measure their degrees of conversion (DC) and to test the correlation between μTBS and DC. METHODS AND MATERIALS: Four commercially available universal adhesives, Prime&Bond universal (PBU), Ecosite Bond (EB), G-Premio Bond (GPB), and Clearfil Universal Bond Quick (UBQ), and one experimental adhesive, UBQ without an amide monomer (UBQ-A), were used in this study. For the μTBS test, midcoronal dentin of 50 human molars was exposed, ground using 600-grit SiC paper, and the adhesives were applied according to the manufacturers' instructions. After resin-composite buildup and 24-hour water storage, one-half of the specimens were subjected to 15,000 thermal cycles. The specimens were sectioned into beams and stressed in tension at a crosshead speed of 1 mm/min until failure. The DC of adhesives applied to dentin was evaluated using attenuated total reflectance Fourier-transform infrared spectroscopy immediately after light-curing. All data were statistically analyzed at a significance level of 0.05. RESULTS: The highest μTBSs were obtained with UBQ, UBQ-A, and PBU, which were not significantly different from each other both after 24 hours and TC. The μTBS of GPB was lower compared with the aforementioned adhesives, but significantly only after TC, and the lowest μTBSs were obtained with EB. TC did not affect the μTBSs of UBQ, UBQ-A, and PBU significantly, but a significant decrease was observed with GPB and EB. The highest DC was obtained with PBU and UBQ, followed by 2-hydroxyethyl methacrylate-rich adhesives UBQ-A and EB, which exhibited significantly lower DCs. The DC of GPB could not be determined because the reference peak at 1608 cm-1 was not detected in its spectra. A significant positive correlation was shown between μTBS and DC after 24 hours (r=0.716) and TC (r=0.856). CONCLUSION: μTBS and DC were positively correlated, more markedly after TC, which suggests that DC may be an important factor for bond durability.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30208 - Dentistry, oral surgery and medicine
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Operative Dentistry
ISSN
0361-7734
e-ISSN
—
Svazek periodika
45
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
556-566
Kód UT WoS článku
000590163900011
EID výsledku v databázi Scopus
2-s2.0-85094964106