The conversion factor for predicting adenoma detection rate from polyp detection rate varies according to colonoscopy indication and patient sex
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10412791" target="_blank" >RIV/00216208:11110/20:10412791 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/20:00118612 RIV/61383082:_____/20:00000752
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=yySG5TCrMI" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=yySG5TCrMI</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/CEJ.0000000000000558" target="_blank" >10.1097/CEJ.0000000000000558</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The conversion factor for predicting adenoma detection rate from polyp detection rate varies according to colonoscopy indication and patient sex
Popis výsledku v původním jazyce
The adenoma detection rate (ADR) is the primary quality indicator for colonoscopies. The polyp detection rate (PDR) is available from administrative data and does not depend on histology verification. The correlation between PDR and ADR and the ADR/PDR conversion factor in preventive colonoscopies were evaluated. In the prospective study, asymptomatic individuals aged 45-75 years with preventive colonoscopy in 2012-2016 were included. Spearman's correlation coefficient was used to assess PDR/ADR for each endoscopist. Conversion factor predicting ADR from PDR was obtained by linear regression and subsequently compared with adenoma to polyp detection rate quotient. One thousand six hundred fourteen preventive colonoscopies performed by 16 endoscopists in 8 screening colonoscopy centres in the Czech Republic were analysed. Correlation between PDR and ADR in all preventive colonoscopies was high and statistically significant (Rs 0.82;P< 0.001). There was a strong correlation between PDR and ADR in men (Rs 0.74;P= 0.002) and in screening colonoscopies (Rs 0.85;P< 0.001). The conversion factor to convert ADR from PDR was 0.72 in all preventive colonoscopies, 0.76 in FOBT+ colonoscopies and 0.67 in screening colonoscopies. ADR may be replaced by PDR in the assessment of colonoscopy quality. The value of the conversion factor varies according to colonoscopy indication and gender of examined individuals; in this Czech study, it was 0.72 in all preventive colonoscopies. The minimum requested ADR of 25 % corresponds to a PDR of 35 %, when converted with the appropriate conversion factor.
Název v anglickém jazyce
The conversion factor for predicting adenoma detection rate from polyp detection rate varies according to colonoscopy indication and patient sex
Popis výsledku anglicky
The adenoma detection rate (ADR) is the primary quality indicator for colonoscopies. The polyp detection rate (PDR) is available from administrative data and does not depend on histology verification. The correlation between PDR and ADR and the ADR/PDR conversion factor in preventive colonoscopies were evaluated. In the prospective study, asymptomatic individuals aged 45-75 years with preventive colonoscopy in 2012-2016 were included. Spearman's correlation coefficient was used to assess PDR/ADR for each endoscopist. Conversion factor predicting ADR from PDR was obtained by linear regression and subsequently compared with adenoma to polyp detection rate quotient. One thousand six hundred fourteen preventive colonoscopies performed by 16 endoscopists in 8 screening colonoscopy centres in the Czech Republic were analysed. Correlation between PDR and ADR in all preventive colonoscopies was high and statistically significant (Rs 0.82;P< 0.001). There was a strong correlation between PDR and ADR in men (Rs 0.74;P= 0.002) and in screening colonoscopies (Rs 0.85;P< 0.001). The conversion factor to convert ADR from PDR was 0.72 in all preventive colonoscopies, 0.76 in FOBT+ colonoscopies and 0.67 in screening colonoscopies. ADR may be replaced by PDR in the assessment of colonoscopy quality. The value of the conversion factor varies according to colonoscopy indication and gender of examined individuals; in this Czech study, it was 0.72 in all preventive colonoscopies. The minimum requested ADR of 25 % corresponds to a PDR of 35 %, when converted with the appropriate conversion factor.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30219 - Gastroenterology and hepatology
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Journal of Cancer Prevention
ISSN
0959-8278
e-ISSN
—
Svazek periodika
29
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
294-302
Kód UT WoS článku
000545919600003
EID výsledku v databázi Scopus
2-s2.0-85086620187