Pressure and flow properties of dual-lumen cannulae for extracorporeal membrane oxygenation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10418518" target="_blank" >RIV/00216208:11110/20:10418518 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064165:_____/20:10418518
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=vsL.uGMmqc" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=vsL.uGMmqc</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/0267659120926009" target="_blank" >10.1177/0267659120926009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pressure and flow properties of dual-lumen cannulae for extracorporeal membrane oxygenation
Popis výsledku v původním jazyce
Introduction: In the last decade, dual-lumen cannulae have been increasingly applied in patients undergoing extracorporeal life support. Well-performing vascular access is crucial for efficient extracorporeal membrane oxygenation support; thus, guidance for proper cannulae size is required. Pressure-flow charts provided by manufacturers are often based on tests performed using water, rarely blood. However, blood is a shear-thinning and viscoelastic fluid characterized by different flow properties than water. Methods: We performed a study evaluating pressure-flow curves during standardized conditions using human whole blood in two commonly available dual-lumen cannulae used in neonates, pediatric, and adult patients. Results were merged and compared with the manufacturer's corresponding curves obtained from the public domain. Results: The results showed that using blood as compared with water predominantly influenced drainage flow. A 10-80% higher pressure-drop was needed to obtain same drainage flow (hematocrit of 26%) compared with manufacturer's water charts in 13-31 Fr bi-caval dual-lumen cannulae. The same net difference was found in cavo-atrial cannulae (16-32 Fr), where a lower drainage pressure was required (Hct of 26%) compared with the manufacturer's test using blood with an Hct of 33%. Return pressure-flow data were similar, independent whether pumping blood or water, to the data reported by manufacturers. Conclusion: Non-standardized testing of pressure-flow properties of extracorporeal membrane oxygenation dual-lumen cannulae prevents an adequate prediction of pressure-flow results when these cannulae are used in patients. Properties of dual-lumen cannulae may vary between sizes within same cannula family, in particular concerning the drainage flow.
Název v anglickém jazyce
Pressure and flow properties of dual-lumen cannulae for extracorporeal membrane oxygenation
Popis výsledku anglicky
Introduction: In the last decade, dual-lumen cannulae have been increasingly applied in patients undergoing extracorporeal life support. Well-performing vascular access is crucial for efficient extracorporeal membrane oxygenation support; thus, guidance for proper cannulae size is required. Pressure-flow charts provided by manufacturers are often based on tests performed using water, rarely blood. However, blood is a shear-thinning and viscoelastic fluid characterized by different flow properties than water. Methods: We performed a study evaluating pressure-flow curves during standardized conditions using human whole blood in two commonly available dual-lumen cannulae used in neonates, pediatric, and adult patients. Results were merged and compared with the manufacturer's corresponding curves obtained from the public domain. Results: The results showed that using blood as compared with water predominantly influenced drainage flow. A 10-80% higher pressure-drop was needed to obtain same drainage flow (hematocrit of 26%) compared with manufacturer's water charts in 13-31 Fr bi-caval dual-lumen cannulae. The same net difference was found in cavo-atrial cannulae (16-32 Fr), where a lower drainage pressure was required (Hct of 26%) compared with the manufacturer's test using blood with an Hct of 33%. Return pressure-flow data were similar, independent whether pumping blood or water, to the data reported by manufacturers. Conclusion: Non-standardized testing of pressure-flow properties of extracorporeal membrane oxygenation dual-lumen cannulae prevents an adequate prediction of pressure-flow results when these cannulae are used in patients. Properties of dual-lumen cannulae may vary between sizes within same cannula family, in particular concerning the drainage flow.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Perfusion
ISSN
0267-6591
e-ISSN
—
Svazek periodika
35
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
736-744
Kód UT WoS článku
000538270300001
EID výsledku v databázi Scopus
2-s2.0-85085931366