Plasma osteopontin levels, but not its myocardial expression, reflect heart failure severity in recently diagnosed dilated cardiomyopathy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10419362" target="_blank" >RIV/00216208:11110/20:10419362 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064165:_____/20:10419362
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=xiEwinAb2K" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=xiEwinAb2K</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00059-019-4829-0" target="_blank" >10.1007/s00059-019-4829-0</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Plasma osteopontin levels, but not its myocardial expression, reflect heart failure severity in recently diagnosed dilated cardiomyopathy
Popis výsledku v původním jazyce
Background: Elevated levels of the extracellular matrix glycoprotein osteopontin (OPN) may be detected in both myocardium and plasma under various pathological conditions affecting the heart. Several studies demonstrated increased plasma OPN levels in patients with heart failure due to dilated cardiomyopathy (DCM), while other studies showed high OPN expression levels in the myocardium of such patients. However, very little is known about OPN levels in both plasma and myocardium of the same individual with DCM. Therefore, we aimed to compare plasma OPN levels and levels of myocardial OPN expression in patients with recent-onset DCM (Ro-DCM). Methods: We examined plasma OPN as well as creatinine, C-reactive protein (CRP), brain natriuretic peptide (BNP), and troponin I levels in 25 patients with Ro-DCM. Furthermore, all subjects underwent transthoracic echocardiography, selective coronary angiography, and endomyocardial biopsy (EMB) for the assessment of myocardial OPN expression. Results: No significant correlation between myocardial OPN expression and clinical, biochemical, or echocardiographic parameters was found. In log transformation analysis, plasma OPN levels correlated significantly with BNP levels (r = 0.46, p = 0.031), with CRP levels (r = 0.52, p = 0.015), and with early diastolic mitral annular velocity (r = -0.57, p = 0.009). There was a borderline association between the plasma OPN log value and New York Heart Association class (p = 0.053). Conclusion: Plasma OPN levels reflect heart failure severity in patients with Ro-DCM. Myocardial OPN expression is not associated with either plasma OPN levels or markers of heart failure in these individuals.
Název v anglickém jazyce
Plasma osteopontin levels, but not its myocardial expression, reflect heart failure severity in recently diagnosed dilated cardiomyopathy
Popis výsledku anglicky
Background: Elevated levels of the extracellular matrix glycoprotein osteopontin (OPN) may be detected in both myocardium and plasma under various pathological conditions affecting the heart. Several studies demonstrated increased plasma OPN levels in patients with heart failure due to dilated cardiomyopathy (DCM), while other studies showed high OPN expression levels in the myocardium of such patients. However, very little is known about OPN levels in both plasma and myocardium of the same individual with DCM. Therefore, we aimed to compare plasma OPN levels and levels of myocardial OPN expression in patients with recent-onset DCM (Ro-DCM). Methods: We examined plasma OPN as well as creatinine, C-reactive protein (CRP), brain natriuretic peptide (BNP), and troponin I levels in 25 patients with Ro-DCM. Furthermore, all subjects underwent transthoracic echocardiography, selective coronary angiography, and endomyocardial biopsy (EMB) for the assessment of myocardial OPN expression. Results: No significant correlation between myocardial OPN expression and clinical, biochemical, or echocardiographic parameters was found. In log transformation analysis, plasma OPN levels correlated significantly with BNP levels (r = 0.46, p = 0.031), with CRP levels (r = 0.52, p = 0.015), and with early diastolic mitral annular velocity (r = -0.57, p = 0.009). There was a borderline association between the plasma OPN log value and New York Heart Association class (p = 0.053). Conclusion: Plasma OPN levels reflect heart failure severity in patients with Ro-DCM. Myocardial OPN expression is not associated with either plasma OPN levels or markers of heart failure in these individuals.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Herz
ISSN
0340-9937
e-ISSN
—
Svazek periodika
45
Číslo periodika v rámci svazku
Suppl. 1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
105-110
Kód UT WoS článku
000596951500014
EID výsledku v databázi Scopus
2-s2.0-85068845429