Multirater Validation of Peripapillary Hyperreflective Ovoid Mass-like Structures (PHOMS)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10426025" target="_blank" >RIV/00216208:11110/20:10426025 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=U7mrDHlJtZ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=U7mrDHlJtZ</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/01658107.2020.1760891" target="_blank" >10.1080/01658107.2020.1760891</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Multirater Validation of Peripapillary Hyperreflective Ovoid Mass-like Structures (PHOMS)
Popis výsledku v původním jazyce
Peripapillary hyperreflective ovoid mass-like structures (PHOMS) are a new retinal optical coherence tomography (OCT) finding. TheOptic Disc Drusen Studies Consortiumhad made recommendations to distinguish PHOMS from true optic disc drusen (ODD) in 2018. While publications on PHOMS have increased since then, the accuracy of the definition of PHOMS and reliability of detection is unknown. In this multi-rater study, we demonstrate that the 2018 definition of PHOMS resulted in a poor multi-rater kappa of 0.356. We performed a Delphi consensus process to develop a consistent and refined definition of PHOMS with clear principles around the nature of PHOMS and how they differ from normal anatomy. Fifty explanatory teaching slides, provided as supplementary material, allowed our expert group of raters to achieve a good level of agreement (kappa 0.701, 50 OCT scans, 21 raters). We recommend adopting the refined definition for PHOMS.
Název v anglickém jazyce
Multirater Validation of Peripapillary Hyperreflective Ovoid Mass-like Structures (PHOMS)
Popis výsledku anglicky
Peripapillary hyperreflective ovoid mass-like structures (PHOMS) are a new retinal optical coherence tomography (OCT) finding. TheOptic Disc Drusen Studies Consortiumhad made recommendations to distinguish PHOMS from true optic disc drusen (ODD) in 2018. While publications on PHOMS have increased since then, the accuracy of the definition of PHOMS and reliability of detection is unknown. In this multi-rater study, we demonstrate that the 2018 definition of PHOMS resulted in a poor multi-rater kappa of 0.356. We performed a Delphi consensus process to develop a consistent and refined definition of PHOMS with clear principles around the nature of PHOMS and how they differ from normal anatomy. Fifty explanatory teaching slides, provided as supplementary material, allowed our expert group of raters to achieve a good level of agreement (kappa 0.701, 50 OCT scans, 21 raters). We recommend adopting the refined definition for PHOMS.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Neuro-Ophthalmology
ISSN
0165-8107
e-ISSN
—
Svazek periodika
44
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
2
Strana od-do
413-414
Kód UT WoS článku
000552106900001
EID výsledku v databázi Scopus
2-s2.0-85086173129