First Real-Time Imaging of Acute Effects of Arteriovenous Fistula on Regional Distribution of Pulmonary Perfusion in a Novel Porcine Model
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F25%3A10498439" target="_blank" >RIV/00216208:11110/25:10498439 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064165:_____/25:10498439
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=69UQQzXUrt" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=69UQQzXUrt</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33549/physiolres.935411" target="_blank" >10.33549/physiolres.935411</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
First Real-Time Imaging of Acute Effects of Arteriovenous Fistula on Regional Distribution of Pulmonary Perfusion in a Novel Porcine Model
Popis výsledku v původním jazyce
The effects of a large arteriovenous fistula (AVF) on pulmonary perfusion remains to be elucidated. We aimed to study, for the first time, the real-time acute effects of a large AVF on regional distribution of pulmonary perfusion in a novel porcine model. Ten healthy swine under general anesthesia were studied. AVF was created by the connection of femoral artery and femoral vein using high-diameter perfusion cannulas. The AVF was closed and after 30 min of stabilization the first values were recorded. The fistula was then opened, and new data were collected after reaching stable state. Continuous hemodynamic monitoring was performed throughout the protocol. The following functional images were analyzed by electrical impedance tomography (EIT): perfusion and ventilation distributions. We found an increased cardiac output and right ventricular work, which was strongly correlated to an increased pulmonary artery mean pressure (r=0.878, P=0.001). The ventral/dorsal ratio of pulmonary perfusion decreased from 1.9 +/- 1.0 to 1.5 +/- 0.7 (P=0.025). The percentage of total pulmonary blood flow through the dorsal lung region increased from 38.6 +/- 11.7 to 42.2 +/- 10.4 (P=0.016). In conclusion, we have used EIT for the first time for studying the acute effects of a large AVF on regional distribution of pulmonary perfusion in a novel porcine model. In this new experimental model of hyperkinetic circulation caused by AVF, we documented an increased percentage of total pulmonary blood flow through the dorsal lung region and a more homogeneous perfusion distribution.
Název v anglickém jazyce
First Real-Time Imaging of Acute Effects of Arteriovenous Fistula on Regional Distribution of Pulmonary Perfusion in a Novel Porcine Model
Popis výsledku anglicky
The effects of a large arteriovenous fistula (AVF) on pulmonary perfusion remains to be elucidated. We aimed to study, for the first time, the real-time acute effects of a large AVF on regional distribution of pulmonary perfusion in a novel porcine model. Ten healthy swine under general anesthesia were studied. AVF was created by the connection of femoral artery and femoral vein using high-diameter perfusion cannulas. The AVF was closed and after 30 min of stabilization the first values were recorded. The fistula was then opened, and new data were collected after reaching stable state. Continuous hemodynamic monitoring was performed throughout the protocol. The following functional images were analyzed by electrical impedance tomography (EIT): perfusion and ventilation distributions. We found an increased cardiac output and right ventricular work, which was strongly correlated to an increased pulmonary artery mean pressure (r=0.878, P=0.001). The ventral/dorsal ratio of pulmonary perfusion decreased from 1.9 +/- 1.0 to 1.5 +/- 0.7 (P=0.025). The percentage of total pulmonary blood flow through the dorsal lung region increased from 38.6 +/- 11.7 to 42.2 +/- 10.4 (P=0.016). In conclusion, we have used EIT for the first time for studying the acute effects of a large AVF on regional distribution of pulmonary perfusion in a novel porcine model. In this new experimental model of hyperkinetic circulation caused by AVF, we documented an increased percentage of total pulmonary blood flow through the dorsal lung region and a more homogeneous perfusion distribution.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30105 - Physiology (including cytology)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
1802-9973
Svazek periodika
74
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
49-57
Kód UT WoS článku
001478294900006
EID výsledku v databázi Scopus
2-s2.0-105000389656