Auto-fluorescence spectroscopy of colorectal carcinoma: ex vivo study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F06%3A00000509" target="_blank" >RIV/00216208:11120/06:00000509 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Auto-fluorescence spectroscopy of colorectal carcinoma: ex vivo study
Popis výsledku v původním jazyce
Ex-vivo investigation of colorectal tissue by autofluorescence spectroscopy is reported. Wet microscopic mounts of healthy colon mucosa were examined and compared with those prepared from colon mucosa affected by adenocarcinoma. The diagnosis of adenocarcinoma was verified by using clinical and histology means. Fluorescence spectra of tissue samples, excited by blue emitting semiconductor diode have been studied by using portable spectrometer with fixed grating and fibre optic system compatible with endoscope. The study demonstrates differences in both the spectral shape and in the signal intensity in photoluminescence spectra emitted from tissue affected by adenocarcinoma as compared to that of healthy colon mucosa. The overall decrease and the shift of autofluorescence intensity to longer wavelengths have been observed for malignant tissue samples
Název v anglickém jazyce
Auto-fluorescence spectroscopy of colorectal carcinoma: ex vivo study
Popis výsledku anglicky
Ex-vivo investigation of colorectal tissue by autofluorescence spectroscopy is reported. Wet microscopic mounts of healthy colon mucosa were examined and compared with those prepared from colon mucosa affected by adenocarcinoma. The diagnosis of adenocarcinoma was verified by using clinical and histology means. Fluorescence spectra of tissue samples, excited by blue emitting semiconductor diode have been studied by using portable spectrometer with fixed grating and fibre optic system compatible with endoscope. The study demonstrates differences in both the spectral shape and in the signal intensity in photoluminescence spectra emitted from tissue affected by adenocarcinoma as compared to that of healthy colon mucosa. The overall decrease and the shift of autofluorescence intensity to longer wavelengths have been observed for malignant tissue samples
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ND7581" target="_blank" >ND7581: Optická biopsie v diagnostice kolorektální rakoviny</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Optoelectronics and Advanced Materials
ISSN
1454-4164
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
RO - Rumunsko
Počet stran výsledku
4
Strana od-do
396-399
Kód UT WoS článku
000236107300086
EID výsledku v databázi Scopus
—