Intraoperative Reduction of the Scapular Body - A Technical Trick
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F09%3A00001700" target="_blank" >RIV/00216208:11120/09:00001700 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Intraoperative Reduction of the Scapular Body - A Technical Trick
Popis výsledku v původním jazyce
When internal fixation of the scapular neck and body fractures is performed a problem may occur with reduction and retention of position of the lateral border of the scapula during surgery. For this purpose, the authors have developed their own techniqueof stabilization using a K-wire in a novel way. The technique is indicated in a 2-part shear unstable fracture of the lateral border. It cannot be used in fractures with all intercalated segment. A 2.5-mm drill bit is used to drill a 1.5-cm deep hole into the,'medullary cavity" of each of the 2 fragments of the lateral border. A K-wire, 1.5 mm in diameter and 2.5-cm long, is inserted into the distal fragment. The protruding end of the K-wire is inserted into the hole in the proximal fragment. This intramedullary peg helps to maintain reduction and keeps both fragments stable. Subsequently, the lateral border is stabilized with a 3.5-mm reconstruction plate. This technique is quite simple and allows for a temporary stabilization of frag
Název v anglickém jazyce
Intraoperative Reduction of the Scapular Body - A Technical Trick
Popis výsledku anglicky
When internal fixation of the scapular neck and body fractures is performed a problem may occur with reduction and retention of position of the lateral border of the scapula during surgery. For this purpose, the authors have developed their own techniqueof stabilization using a K-wire in a novel way. The technique is indicated in a 2-part shear unstable fracture of the lateral border. It cannot be used in fractures with all intercalated segment. A 2.5-mm drill bit is used to drill a 1.5-cm deep hole into the,'medullary cavity" of each of the 2 fragments of the lateral border. A K-wire, 1.5 mm in diameter and 2.5-cm long, is inserted into the distal fragment. The protruding end of the K-wire is inserted into the hole in the proximal fragment. This intramedullary peg helps to maintain reduction and keeps both fragments stable. Subsequently, the lateral border is stabilized with a 3.5-mm reconstruction plate. This technique is quite simple and allows for a temporary stabilization of frag
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Orthopaedic Trauma
ISSN
0890-5339
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000264609900010
EID výsledku v databázi Scopus
—