Interlaboratory variability of CD34+stem cell enumeration. A pilot study to national external quality assessment within the Czech Republic
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F10%3A00002904" target="_blank" >RIV/00216208:11120/10:00002904 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/10:6329 RIV/00179906:_____/10:10084222 RIV/00064203:_____/10:6329 RIV/00023736:_____/10:00008922 a 2 dalších
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Interlaboratory variability of CD34+stem cell enumeration. A pilot study to national external quality assessment within the Czech Republic
Popis výsledku v původním jazyce
We present the results of a pilot study concerning the interlaboratory variability of CD34+ enumeration. Three surveys, each including a set of samples, were sent to participating Czech flow cytometry laboratories. The efficacy of this exercise was determined by the reduction in interlaboratory variation and the influence of method used on assay outcome. The variability in results of CD34+ enumeration declined with time. The mean coefficient of variation (CV) of measurement among laboratories dropped, from 58% in first survey to 32% in last survey. All tested variables (gating strategy, platform methodology, sample preparation) affected the variability of the assay. Sample preparation method was associated with a significant bias of absolute CD34+ cellcounts. Initially, the outcome of the measurement was also affected by the participating laboratory (identified by a unique laboratory number; ULN). However, laboratories with poorer performance modified their protocols during the study,
Název v anglickém jazyce
Interlaboratory variability of CD34+stem cell enumeration. A pilot study to national external quality assessment within the Czech Republic
Popis výsledku anglicky
We present the results of a pilot study concerning the interlaboratory variability of CD34+ enumeration. Three surveys, each including a set of samples, were sent to participating Czech flow cytometry laboratories. The efficacy of this exercise was determined by the reduction in interlaboratory variation and the influence of method used on assay outcome. The variability in results of CD34+ enumeration declined with time. The mean coefficient of variation (CV) of measurement among laboratories dropped, from 58% in first survey to 32% in last survey. All tested variables (gating strategy, platform methodology, sample preparation) affected the variability of the assay. Sample preparation method was associated with a significant bias of absolute CD34+ cellcounts. Initially, the outcome of the measurement was also affected by the participating laboratory (identified by a unique laboratory number; ULN). However, laboratories with poorer performance modified their protocols during the study,
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NR9268" target="_blank" >NR9268: Role adhezivních molekul a cytokinů v mobilizaci hemopoetických progenitorových buněk u zdravých dárců</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Laboratory Hematology
ISSN
1751-5521
e-ISSN
—
Svazek periodika
32
Číslo periodika v rámci svazku
6, Part
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
000283595500006
EID výsledku v databázi Scopus
—