2. Monitoring of Arrays of Amino Acids in Clinical Samples Using Capillary Electrophoresis with Contactless Conductivity Detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F12%3A43906525" target="_blank" >RIV/00216208:11120/12:43906525 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-1-62703-029-8_2" target="_blank" >http://dx.doi.org/10.1007/978-1-62703-029-8_2</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-1-62703-029-8_2" target="_blank" >10.1007/978-1-62703-029-8_2</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
2. Monitoring of Arrays of Amino Acids in Clinical Samples Using Capillary Electrophoresis with Contactless Conductivity Detection
Popis výsledku v původním jazyce
Capillary electrophoresis (CE) with contactless conductivity detection (C4D) is readily applicable to determinations of amino acids in clinical samples. Most of these analyses employ long separation pathways. This chapter describes CE/C4D determinationsof 28 biogenic amino acids in a short capillary with an effective length of 18 cm. All the test amino acids can be mutually separated in electrolytes of 0.5 to 10 mol/L acetic acid. The time of analysis does not exceed 6 min., the limits of detection vary from 0.1 to 1.7 ?mol/L for all the analytes. The pretreatment of the biological material is very simple, consisting of removal of proteins by an addition of acetonitrile and subsequent filtration. The procedure has been successfully applied to determinations of the whole amino acid spectra in blood plasma, urine, saliva, cerebrospinal and amniotic fluid samples
Název v anglickém jazyce
2. Monitoring of Arrays of Amino Acids in Clinical Samples Using Capillary Electrophoresis with Contactless Conductivity Detection
Popis výsledku anglicky
Capillary electrophoresis (CE) with contactless conductivity detection (C4D) is readily applicable to determinations of amino acids in clinical samples. Most of these analyses employ long separation pathways. This chapter describes CE/C4D determinationsof 28 biogenic amino acids in a short capillary with an effective length of 18 cm. All the test amino acids can be mutually separated in electrolytes of 0.5 to 10 mol/L acetic acid. The time of analysis does not exceed 6 min., the limits of detection vary from 0.1 to 1.7 ?mol/L for all the analytes. The pretreatment of the biological material is very simple, consisting of removal of proteins by an addition of acetonitrile and subsequent filtration. The procedure has been successfully applied to determinations of the whole amino acid spectra in blood plasma, urine, saliva, cerebrospinal and amniotic fluid samples
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F10%2F1231" target="_blank" >GAP206/10/1231: Nové elekroforetické přístupy k monitorování hladin neurotransmiterů bolesti v mozku vyšších živočichů</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Clinical Applications of Capillary Electrophoresis: Methods and Protocols
ISBN
978-1-62703-028-1
Počet stran výsledku
11
Strana od-do
13-23
Počet stran knihy
311
Název nakladatele
Humana Press
Místo vydání
New York
Kód UT WoS kapitoly
—