Right subclavian approach in transcatheter aortic valve implantation using the CoreValve prosthesis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F12%3A43906997" target="_blank" >RIV/00216208:11120/12:43906997 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064173:_____/12:43906997
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.crvasa.2012.08.002" target="_blank" >http://dx.doi.org/10.1016/j.crvasa.2012.08.002</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.crvasa.2012.08.002" target="_blank" >10.1016/j.crvasa.2012.08.002</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Right subclavian approach in transcatheter aortic valve implantation using the CoreValve prosthesis
Popis výsledku v původním jazyce
Typically, transfemoral access using the self-expanding CoreValve Revalving System is the initial default strategy in patients undergoing transcatheter aortic valve implantation (TAVI). Subclavian access is a potential alternative to the femoral route inpatients with peripheral vascular disease. The left subclavian is preferred due to the favourable orientation of the delivery system through the aortic arch and annulus. However, right subclavian access may also be feasible in cases with specific anatomical conditions of the aortic root and valve annulus. We present a case where TAVI using the CoreValve prosthesis was performed via right subclavian artery with good 1 year outcome
Název v anglickém jazyce
Right subclavian approach in transcatheter aortic valve implantation using the CoreValve prosthesis
Popis výsledku anglicky
Typically, transfemoral access using the self-expanding CoreValve Revalving System is the initial default strategy in patients undergoing transcatheter aortic valve implantation (TAVI). Subclavian access is a potential alternative to the femoral route inpatients with peripheral vascular disease. The left subclavian is preferred due to the favourable orientation of the delivery system through the aortic arch and annulus. However, right subclavian access may also be feasible in cases with specific anatomical conditions of the aortic root and valve annulus. We present a case where TAVI using the CoreValve prosthesis was performed via right subclavian artery with good 1 year outcome
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cor et Vasa
ISSN
0010-8650
e-ISSN
—
Svazek periodika
54
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
3
Strana od-do
"e326"-"e328"
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—