Very fast electrophoretic separation on commercial instruments using a combination of two capillaries with different internal diameters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F13%3A43906901" target="_blank" >RIV/00216208:11120/13:43906901 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/13:10133792
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elps.201200524" target="_blank" >http://dx.doi.org/10.1002/elps.201200524</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elps.201200524" target="_blank" >10.1002/elps.201200524</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Very fast electrophoretic separation on commercial instruments using a combination of two capillaries with different internal diameters
Popis výsledku v původním jazyce
A capillary formed by connecting a 9.7 cm long separation capillary with id 25 ?m with an auxiliary 22.9 cm long capillary with id 100 ?m (coupled capillary) was tested for electrophoretic separation at high electric field intensities. The coupled capillary was placed in the cassette of a standard electrophoresis apparatus. It was used in the short-end injection mode for separation of a mixture of dopamine, noradrenaline and adrenaline in a background electrolyte of 20 mM citric acid/NaOH, pH 3.2. An intensity of 2.7 kV cm(-1) was attained in the separation part of the capillary at a separation voltage of 30 kV, which is 2.9 times more than maximum intensity value attainable in a capillary with the same length with uniform id. At these high electric field intensities, the migration times of the tested neurotransmitters had values of 12.3 to 13.3 s and the attained separation efficiency was between 2350 and 2760 plates s(-1) . It is thus demonstrated that an effective separation instrum
Název v anglickém jazyce
Very fast electrophoretic separation on commercial instruments using a combination of two capillaries with different internal diameters
Popis výsledku anglicky
A capillary formed by connecting a 9.7 cm long separation capillary with id 25 ?m with an auxiliary 22.9 cm long capillary with id 100 ?m (coupled capillary) was tested for electrophoretic separation at high electric field intensities. The coupled capillary was placed in the cassette of a standard electrophoresis apparatus. It was used in the short-end injection mode for separation of a mixture of dopamine, noradrenaline and adrenaline in a background electrolyte of 20 mM citric acid/NaOH, pH 3.2. An intensity of 2.7 kV cm(-1) was attained in the separation part of the capillary at a separation voltage of 30 kV, which is 2.9 times more than maximum intensity value attainable in a capillary with the same length with uniform id. At these high electric field intensities, the migration times of the tested neurotransmitters had values of 12.3 to 13.3 s and the attained separation efficiency was between 2350 and 2760 plates s(-1) . It is thus demonstrated that an effective separation instrum
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrophoresis
ISSN
0173-0835
e-ISSN
—
Svazek periodika
34
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
552-556
Kód UT WoS článku
000315169800011
EID výsledku v databázi Scopus
—