Cerebral tissue oxygenation index, cardiac output and superior vena cava flow in infants with birth weight less than 1250 grams in the first 48 hours of life
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F13%3A43907480" target="_blank" >RIV/00216208:11120/13:43907480 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00023698:_____/13:#0000152
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.earlhumdev.2013.04.004" target="_blank" >http://dx.doi.org/10.1016/j.earlhumdev.2013.04.004</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.earlhumdev.2013.04.004" target="_blank" >10.1016/j.earlhumdev.2013.04.004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Cerebral tissue oxygenation index, cardiac output and superior vena cava flow in infants with birth weight less than 1250 grams in the first 48 hours of life
Popis výsledku v původním jazyce
Near-infrared spectroscopy is a non-invasive method of assessing cerebral oxygenation. Functional echocardiography is increasingly used by neonatologists in the assessment of cardiovascular function. Aims: To correlate cerebral tissue oxygenation index (cTOI) and cardiac output in infants less than 1250 g at 6, 12,24 and 48 hours of age. Study design: A prospective observational study. Subjects: Newborns with birth weight < 1250 g. Outcome measures: Serial assessments of superior vena cava (SVC) flow, right and left ventricular outputs, ductus arteriosus and cTOI were performed at 6, 12, 24 and 48 hours of age. Clinical parameters, including mean blood pressure, mean airway pressure, blood gas parameters and oxygen saturations were recorded. Results: 22 neonates were enrolled following parental consent. The mean birth weight was 851 g (SD +/- 201), mean gestational age was 25.9 weeks (SD +/- 1.7). Mean SVC flow at 6 hours of age was 56.8 ml/kg/min and increased to 68.6 ml/kg/min at 48
Název v anglickém jazyce
Cerebral tissue oxygenation index, cardiac output and superior vena cava flow in infants with birth weight less than 1250 grams in the first 48 hours of life
Popis výsledku anglicky
Near-infrared spectroscopy is a non-invasive method of assessing cerebral oxygenation. Functional echocardiography is increasingly used by neonatologists in the assessment of cardiovascular function. Aims: To correlate cerebral tissue oxygenation index (cTOI) and cardiac output in infants less than 1250 g at 6, 12,24 and 48 hours of age. Study design: A prospective observational study. Subjects: Newborns with birth weight < 1250 g. Outcome measures: Serial assessments of superior vena cava (SVC) flow, right and left ventricular outputs, ductus arteriosus and cTOI were performed at 6, 12, 24 and 48 hours of age. Clinical parameters, including mean blood pressure, mean airway pressure, blood gas parameters and oxygen saturations were recorded. Results: 22 neonates were enrolled following parental consent. The mean birth weight was 851 g (SD +/- 201), mean gestational age was 25.9 weeks (SD +/- 1.7). Mean SVC flow at 6 hours of age was 56.8 ml/kg/min and increased to 68.6 ml/kg/min at 48
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FK - Gynekologie a porodnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Early Human Development
ISSN
0378-3782
e-ISSN
—
Svazek periodika
89
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
IE - Irsko
Počet stran výsledku
4
Strana od-do
449-452
Kód UT WoS článku
000319713500001
EID výsledku v databázi Scopus
—