Electrokinetic injection of samples into a short electrophoretic capillary controlled by piezoelectric micropumps
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F16%3A43910457" target="_blank" >RIV/00216208:11120/16:43910457 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/16:10323515
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elps.201500464" target="_blank" >http://dx.doi.org/10.1002/elps.201500464</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elps.201500464" target="_blank" >10.1002/elps.201500464</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrokinetic injection of samples into a short electrophoretic capillary controlled by piezoelectric micropumps
Popis výsledku v původním jazyce
Electrokinetic sample injection using two piezoelectric micropumps has been proposed for electrophoresis in short capillaries. The sample is brought to the injection end of the capillary using one of them. Then the high-voltage source is turned on and the sample is injected electrokinetically for a defined time. The injection is terminated by removal of the sample zone by the flowing separation electrolyte pumped by the second piezoelectric micropump. The RSD value, expressing the repeatability of the injection, does not exceed 4%. The injection apparatus does not contain any mobile mechanical components, there is no movement of the capillary and both of its ends remain constantly in the solution during both the sample injection and separation. Thus the micropumps replace the six-way injection valve and linear pump in similar types of injection apparatuses. The injection was tested in the separation and determination of ammonium and potassium ions in two samples of mineral fertilisers.
Název v anglickém jazyce
Electrokinetic injection of samples into a short electrophoretic capillary controlled by piezoelectric micropumps
Popis výsledku anglicky
Electrokinetic sample injection using two piezoelectric micropumps has been proposed for electrophoresis in short capillaries. The sample is brought to the injection end of the capillary using one of them. Then the high-voltage source is turned on and the sample is injected electrokinetically for a defined time. The injection is terminated by removal of the sample zone by the flowing separation electrolyte pumped by the second piezoelectric micropump. The RSD value, expressing the repeatability of the injection, does not exceed 4%. The injection apparatus does not contain any mobile mechanical components, there is no movement of the capillary and both of its ends remain constantly in the solution during both the sample injection and separation. Thus the micropumps replace the six-way injection valve and linear pump in similar types of injection apparatuses. The injection was tested in the separation and determination of ammonium and potassium ions in two samples of mineral fertilisers.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-03139S" target="_blank" >GA15-03139S: Nové elektroforetické přístupy pro studium obezity a diabetu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrophoresis
ISSN
0173-0835
e-ISSN
—
Svazek periodika
37
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
595-600
Kód UT WoS článku
000370657900005
EID výsledku v databázi Scopus
—