Hydrodynamic sample injection into short electrophoretic capillary in systems with a flow-gating interface
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F17%3A43912636" target="_blank" >RIV/00216208:11120/17:43912636 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/17:10359494
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.chroma.2016.12.029" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2016.12.029</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2016.12.029" target="_blank" >10.1016/j.chroma.2016.12.029</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hydrodynamic sample injection into short electrophoretic capillary in systems with a flow-gating interface
Popis výsledku v původním jazyce
An electrophoretic apparatus with a flow-gating interface has been developed, enabling hydrodynamic sequence injection of the sample into the separation capillary from the liquid flow by underpressure generated in the outlet electrophoretic vessel. The properties of the apparatus were tested on an artificial sample of an equimolar mixture of 100μM potassium and sodium ions and arginine. The repeatability of the injection of the tested ions expressed as RSD (in%) for the peak area, peak height and migration time was in the range 0.76-2.08, 0.18-0.68 and 0.28-0.48, respectively. Under optimum conditions, the apparatus was used for sequence monitoring of the reaction between the antidiabetic drug phenyl biguanide and the glycation agent methyl glyoxal. The reaction solution was continuously sampled by a microdialysis probe from a thermostated external vessel using a syringe pump at a flow rate of 3μLmin(-1) and was injected into a separation capillary at certain time intervals. The electrophoretic separation progressed in a capillary with an internal diameter of 50μm with a length of 11.5cm and was monitored using a contactless conductivity detector..
Název v anglickém jazyce
Hydrodynamic sample injection into short electrophoretic capillary in systems with a flow-gating interface
Popis výsledku anglicky
An electrophoretic apparatus with a flow-gating interface has been developed, enabling hydrodynamic sequence injection of the sample into the separation capillary from the liquid flow by underpressure generated in the outlet electrophoretic vessel. The properties of the apparatus were tested on an artificial sample of an equimolar mixture of 100μM potassium and sodium ions and arginine. The repeatability of the injection of the tested ions expressed as RSD (in%) for the peak area, peak height and migration time was in the range 0.76-2.08, 0.18-0.68 and 0.28-0.48, respectively. Under optimum conditions, the apparatus was used for sequence monitoring of the reaction between the antidiabetic drug phenyl biguanide and the glycation agent methyl glyoxal. The reaction solution was continuously sampled by a microdialysis probe from a thermostated external vessel using a syringe pump at a flow rate of 3μLmin(-1) and was injected into a separation capillary at certain time intervals. The electrophoretic separation progressed in a capillary with an internal diameter of 50μm with a length of 11.5cm and was monitored using a contactless conductivity detector..
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-03139S" target="_blank" >GA15-03139S: Nové elektroforetické přístupy pro studium obezity a diabetu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1480
Číslo periodika v rámci svazku
January
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
93-98
Kód UT WoS článku
000392686500010
EID výsledku v databázi Scopus
2-s2.0-85006992502