A review of superior vena cava flow measurement in the neonate by functional echocardiography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F17%3A43912888" target="_blank" >RIV/00216208:11120/17:43912888 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00023698:_____/17:N0000028
Výsledek na webu
<a href="http://dx.doi.org/10.1111/apa.13584" target="_blank" >http://dx.doi.org/10.1111/apa.13584</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/apa.13584" target="_blank" >10.1111/apa.13584</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A review of superior vena cava flow measurement in the neonate by functional echocardiography
Popis výsledku v původním jazyce
Neonatologists have begun using superior vena cava flow as assessed by functional echocardiography to facilitate real-time decision-making on cardiovascular care. This review aims to describe the basis of the technique, summarise the evidence for its use and compare the technique to existing clinical, biochemical and radiological techniques for assessing neonatal circulatory status. Conclusion: Although echocardiographic measurements of superior vena cava flow, like other measures of perfusion, are not perfect, their noninvasive nature and ability to facilitate real-time decision-making means that at present, they remain the best available methodology of monitoring central perfusion in the neonatal population.
Název v anglickém jazyce
A review of superior vena cava flow measurement in the neonate by functional echocardiography
Popis výsledku anglicky
Neonatologists have begun using superior vena cava flow as assessed by functional echocardiography to facilitate real-time decision-making on cardiovascular care. This review aims to describe the basis of the technique, summarise the evidence for its use and compare the technique to existing clinical, biochemical and radiological techniques for assessing neonatal circulatory status. Conclusion: Although echocardiographic measurements of superior vena cava flow, like other measures of perfusion, are not perfect, their noninvasive nature and ability to facilitate real-time decision-making means that at present, they remain the best available methodology of monitoring central perfusion in the neonatal population.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30209 - Paediatrics
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Paediatrica
ISSN
0803-5253
e-ISSN
—
Svazek periodika
106
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
22-29
Kód UT WoS článku
000390597700007
EID výsledku v databázi Scopus
2-s2.0-84995527845