Falsely elevated human epididymis protein 4 results and Risk of Ovarian Malignancy Algorithm in polymorbid women after solid organ transplantation: A pilot and case-control study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F18%3A43916560" target="_blank" >RIV/00216208:11120/18:43916560 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00023001:_____/18:00077076
Výsledek na webu
<a href="https://doi.org/10.1002/jcla.22432" target="_blank" >https://doi.org/10.1002/jcla.22432</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jcla.22432" target="_blank" >10.1002/jcla.22432</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Falsely elevated human epididymis protein 4 results and Risk of Ovarian Malignancy Algorithm in polymorbid women after solid organ transplantation: A pilot and case-control study
Popis výsledku v původním jazyce
BACKGROUND: Cancer prevention is essential after transplantation (Tx). The use of HE4 and Risk of Ovarian Malignancy Algorithm (ROMA) is recommended as a tool for selective ovarian cancer screening; however, creatinine is a known confounder. This study assessed the reliability of HE4, CA125, and ROMA after Tx. METHODS: We matched a total of 202 women without gynecological malignancies and 236 men by age and serum creatinine. Each pair consisted of a patient after Tx (kidney, liver, heart, and pancreas) and a diseased but non-Tx consecutive patient. Serum HE4, CA125 (Roche Cobas 6000), and creatinine (enzymatic, Abbott Architect) were measured in all patients. RESULTS: Creatinine correlated with HE4 (women: r = .864, P < .0001; men: r = .848, P < .0001). Age correlated slightly with HE4 in women (r = .250, P < .005) and men (r = .240, P < .0005). HE4 in women after Tx (median of 84.8 pmol/L) was significantly higher than non-Tx women (53.7 pmol/L, P < .0001) in the reference range of serum creatinine. Neither HE4 nor CA125 correlated with tacrolimus concentration, but anemia, hyperparathyroidism, kidney, liver, and lung diseases were possible confounders for HE4 after transplantation (P < .05). CONCLUSION: Human epididymis protein 4 (HE4) was significantly increased in women after solid organ transplantation compared to levels without transplants matched by age and serum creatinine. HE4 results may be misleading in these patients.
Název v anglickém jazyce
Falsely elevated human epididymis protein 4 results and Risk of Ovarian Malignancy Algorithm in polymorbid women after solid organ transplantation: A pilot and case-control study
Popis výsledku anglicky
BACKGROUND: Cancer prevention is essential after transplantation (Tx). The use of HE4 and Risk of Ovarian Malignancy Algorithm (ROMA) is recommended as a tool for selective ovarian cancer screening; however, creatinine is a known confounder. This study assessed the reliability of HE4, CA125, and ROMA after Tx. METHODS: We matched a total of 202 women without gynecological malignancies and 236 men by age and serum creatinine. Each pair consisted of a patient after Tx (kidney, liver, heart, and pancreas) and a diseased but non-Tx consecutive patient. Serum HE4, CA125 (Roche Cobas 6000), and creatinine (enzymatic, Abbott Architect) were measured in all patients. RESULTS: Creatinine correlated with HE4 (women: r = .864, P < .0001; men: r = .848, P < .0001). Age correlated slightly with HE4 in women (r = .250, P < .005) and men (r = .240, P < .0005). HE4 in women after Tx (median of 84.8 pmol/L) was significantly higher than non-Tx women (53.7 pmol/L, P < .0001) in the reference range of serum creatinine. Neither HE4 nor CA125 correlated with tacrolimus concentration, but anemia, hyperparathyroidism, kidney, liver, and lung diseases were possible confounders for HE4 after transplantation (P < .05). CONCLUSION: Human epididymis protein 4 (HE4) was significantly increased in women after solid organ transplantation compared to levels without transplants matched by age and serum creatinine. HE4 results may be misleading in these patients.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Clinical Laboratory Analysis
ISSN
0887-8013
e-ISSN
—
Svazek periodika
32
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
"Article e22432"
Kód UT WoS článku
000438900600029
EID výsledku v databázi Scopus
2-s2.0-85044347587