Mortality prediction after transcatheter treatment of failed bioprosthetic aortic valves utilizing various international scoring systems: Insights from the Valve-in-Valve International Data (VIVID)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F18%3A43916951" target="_blank" >RIV/00216208:11120/18:43916951 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1002/ccd.27714" target="_blank" >https://doi.org/10.1002/ccd.27714</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/ccd.27714" target="_blank" >10.1002/ccd.27714</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mortality prediction after transcatheter treatment of failed bioprosthetic aortic valves utilizing various international scoring systems: Insights from the Valve-in-Valve International Data (VIVID)
Popis výsledku v původním jazyce
BACKGROUND: Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS). OBJECTIVE: The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all-cause mortality after transcatheter aortic valve-in-valve (ViV) implantations, which was not assessed before. METHODS: Using the Valve-in-Valve International Data (VIVID) registry, a total of 1,550 patients from 110 centers were included. The study compared the observed 30-day overall mortality vs. the respective predicted mortalities calculated by risk scores. The accuracy of prediction models was assessed based on calibration and discrimination. RESULTS: Observed mortality at 30 days was 5.3%, while average expected mortalities by LES, ES II and STS were 29.49 (+- 17.2), 14.59 (+- 8.6), and 9.61 (+- 8.51), respectively. All three risk scores overestimated 30-day mortality with ratios of 0.176 (95% CI 0.138-0.214), 0.342 (95% CI 0.264-0.419), and 0.536 (95% CI 0.421-0.651), respectively. 30-day mortality ROC curves demonstrated that ES II had the largest AUC at 0.722, followed by STS at 0.704, and LES at 0.698. CONCLUSIONS: All three scores overestimated mortality at 30 days with ES II showing the highest predictability compared to LES and STS; and therefore, should be recommended for ViV procedures. There is a need for a dedicated scoring system for patients undergoing ViV interventions.
Název v anglickém jazyce
Mortality prediction after transcatheter treatment of failed bioprosthetic aortic valves utilizing various international scoring systems: Insights from the Valve-in-Valve International Data (VIVID)
Popis výsledku anglicky
BACKGROUND: Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS). OBJECTIVE: The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all-cause mortality after transcatheter aortic valve-in-valve (ViV) implantations, which was not assessed before. METHODS: Using the Valve-in-Valve International Data (VIVID) registry, a total of 1,550 patients from 110 centers were included. The study compared the observed 30-day overall mortality vs. the respective predicted mortalities calculated by risk scores. The accuracy of prediction models was assessed based on calibration and discrimination. RESULTS: Observed mortality at 30 days was 5.3%, while average expected mortalities by LES, ES II and STS were 29.49 (+- 17.2), 14.59 (+- 8.6), and 9.61 (+- 8.51), respectively. All three risk scores overestimated 30-day mortality with ratios of 0.176 (95% CI 0.138-0.214), 0.342 (95% CI 0.264-0.419), and 0.536 (95% CI 0.421-0.651), respectively. 30-day mortality ROC curves demonstrated that ES II had the largest AUC at 0.722, followed by STS at 0.704, and LES at 0.698. CONCLUSIONS: All three scores overestimated mortality at 30 days with ES II showing the highest predictability compared to LES and STS; and therefore, should be recommended for ViV procedures. There is a need for a dedicated scoring system for patients undergoing ViV interventions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Catheterization & Cardiovascular Interventions
ISSN
1522-1946
e-ISSN
—
Svazek periodika
92
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
1163-1170
Kód UT WoS článku
000451188300032
EID výsledku v databázi Scopus
2-s2.0-85053233450