Sensation and pain thresholds of transcranial stimulation with direct and alternating electric current
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F18%3A43917364" target="_blank" >RIV/00216208:11120/18:43917364 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.23919/EMF-MED.2018.8526014" target="_blank" >https://doi.org/10.23919/EMF-MED.2018.8526014</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.23919/EMF-MED.2018.8526014" target="_blank" >10.23919/EMF-MED.2018.8526014</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sensation and pain thresholds of transcranial stimulation with direct and alternating electric current
Popis výsledku v původním jazyce
Transcranial electrical stimulation with direct and alternating current (tDCS and tACS) is non-invasive methods used for therapeutic purposes as well as cognitive effects. The sensation and the pain thresholds as well as the adverse effects were recorded for anodal tDCS, cathodal tDCS, tACS at 6 Hz, 10 Hz, 20 Hz and 40 Hz administered to healthy participants via sponge electrodes placed at AF7 and AF8. The lowest sensation thresholds were found for 10-40 Hz tACS. The pain thresholds less than 2.0 mA were reached only with anodal tDCS in a few participants. Mild prickle, itching, tickling or tingling were referred by all participants for all kinds of stimulations with current thresholds highly scattered. Feelings of burning or tingling were observed in more than half participants mostly for anodal tDCS. Phosphenes were referred by most participants with tACS even for very low currents.
Název v anglickém jazyce
Sensation and pain thresholds of transcranial stimulation with direct and alternating electric current
Popis výsledku anglicky
Transcranial electrical stimulation with direct and alternating current (tDCS and tACS) is non-invasive methods used for therapeutic purposes as well as cognitive effects. The sensation and the pain thresholds as well as the adverse effects were recorded for anodal tDCS, cathodal tDCS, tACS at 6 Hz, 10 Hz, 20 Hz and 40 Hz administered to healthy participants via sponge electrodes placed at AF7 and AF8. The lowest sensation thresholds were found for 10-40 Hz tACS. The pain thresholds less than 2.0 mA were reached only with anodal tDCS in a few participants. Mild prickle, itching, tickling or tingling were referred by all participants for all kinds of stimulations with current thresholds highly scattered. Feelings of burning or tingling were observed in more than half participants mostly for anodal tDCS. Phosphenes were referred by most participants with tACS even for very low currents.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
<a href="/cs/project/NV15-31538A" target="_blank" >NV15-31538A: Diagnostika a terapie orofaciální bolesti</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2018 EMF-Med 1st World Conference on Biomedical Applications of Electromagnetic Fields
ISBN
978-953-290-079-8
ISSN
—
e-ISSN
neuvedeno
Počet stran výsledku
2
Strana od-do
"Article 8526014"
Název nakladatele
IEEE
Místo vydání
New Jersey
Místo konání akce
Split, Croatia
Datum konání akce
10. 9. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce